A4 Technical Data - Electrolux ZHTAROW User Manual

Table of Contents

Advertisement

A4
TECHNICAL DATA
MODEL
Supply voltage:
• three-phase version
- convertible to
- convertible to
Frequency
Max. power input (three-phase version)
Max. power input (single-phase version)
Boiler heating elements
Tank heating elements
Water supply pressure
Water supply temperature
Water supply hardness
Rinse cycle water consumption
Boiler capacity
Tank capacity
Standard cycle time:
- Thermal label mode
- High productivity mode
Legal noise level
Protection rating
Net weight
Power supply cable
Supply cord diameter (min - max value)
(**) = Reduce the power of the boiler from 12 kW to 6kW as shown in the circuit diagram.
400..415 V 3N
C
9,9 kW
-
15,9 kW
5X6
C = Power supply cable
S = On/Off switch
Standard cycle time may vary should the inlet water temperature be different from that indicated above.
EHTAROW / ZHTAROW /
OHTAROW
V
400...415- 3N~
V
220...240- 3~
V
220...240- 1N~ (**)
Hz
50
kW
15,9
kW
9,9
kW
6,0 + 6,0 (**)
kW
3,0
kPa [bar]
50...700 [0,5...7]
°C
10 ... 60
°fH [°dH ]
14 [8] max
l
3,0
l
12
l
42
sec.
77-90-150
sec.
54-90-150
dB(A)
<68
IPX4
kg
98
H07RN-F
mm
18-25
Table 1
220...240 V 3
S
C
-
-
40 A 3P+N
4X10
Table 2
EHTAROW60 / ZHTAROW60 /
OHTAROW60
220...240- 3~ N~
400...415- 3
220...240- 1N~ (**)
60
15,9
9,9
6,0 + 6,0 (**)
3,0
50...700 [0,5...7]
10 ... 60
14 [8] max
3,0
12
42
77-90-150
54-90-150
<68
IPX4
98
H07RN-F
18-25
220...240 V 1N
S
C
-
3X10
60 A 3P
-
S
60 A 1P+N
-
5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ehtarow60Zhtarow60EhtarowOhtarow60Ohtarow

Table of Contents