Table of Content 1. Introduction....................................................1 2. Appearance....................................................2 3. Main Features...................................................3 4.Set up Instruction..................................................3 5. Data Report....................................................4 6. Installation....................................................6 7. Important Maintenance Instruction............................................7 8. FCC Statement..................................................7...
1. Introduction R311G is a long-distance light sensor based on the LoRaWAN open protocol (Class A). LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long distance and low power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance. Widely used in long-distance, low-data wireless communications.
Low power consumption and long battery life Note*: Battery life is determined by the sensor reporting frequency and other variables, please refer to http://www.netvox.com.tw/electric/electric_calc.html On this website, users can find battery life time for varied models at different configurations.
4.Set up Instruction On/Off Insert batteries. Power on (users may need a flat blade screwdriver to open); insert two sections of 3V CR2450 button batteries and close the battery cover.) Turn on Press any function key till green and red indicator flashes once. Turn off Press and hold the function key for 5 seconds till green indicator flashes for 20 times.
Illuminance---- 0x32(50lux) Note: MinInterval is the sampling period for the Sensor. Sampling period >= MinInterval. he reported data is decoded by the Netvox LoRaWAN Application Command document and http://www.netvox.com.cn:8888/page/index Data report configuration and sending period are as following: Min Interval...
Example#3 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Users push the button, Wakes up and collects data REPORTS 2.7V. Wakes up and collects data 2.7V |2.7-2.8|=0.1 Recalculate MaxTime. 2.7V Does not report REPORTS 2.7V sleeping sleeping...
Page 8
(default 50 LUX), the currently detected illumination value is sent. This figure shows the scene where the light sensor (R311G) is applied in the office. It can also be applied to the following scenarios: Home ...
(3) The battery installation method is shown in the figure below (battery with "+" facing outward). Note: To install the battery, use a screwdriver or similar tool to assist in opening the battery cover. 7. Important Maintenance Instruction Your device is a product of superior design and craftsmanship and should be used with care. The following suggestions will help you use the warranty service effectively.
Need help?
Do you have a question about the R311G and is the answer not in the manual?
Questions and answers