58300000187895 ARA EN A
Cooking Mode
Elements Used
Broil, Bake,
Conv Fan
Convection Roast
Conv Element,
Convection
Conv Fan
Multi-rack
Broil, Bake,
Conv Fan
Pizza
Table 3 Active elements by cooking mode

4.2.2 Element Duty Cycles

The Preheat, Fast Preheat and Regulate tables that follow reflect the
element cycling times for the oven cavities in induction ranges. A two-
point control is used for all cooking modes.
Table 4 Element duty cycles during Preheat
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
Description
Upper and lower elements cycle to
maintain oven temperature and air is
circulated by the convection fan; more
intense heat from the upper element is
used than the lower.
Heat is generated by the convection ring
element and circulated by the convection
fan.
Upper and lower elements cycle to
maintain oven temperature, and the heat
is circulated by the convection fan
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
MAY 2015
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Table 5 Element duty cycles during Fast Preheat
Table 6 Element duty cycles during Regulate
4.2.3

Setting Temperature Offsets

In some cases, it may be necessary to adjust the oven temperature if
the customer reports that food is consistently under- or over-cooked,
even though the oven is operating normally. Temperature Offsets can
Page 9 of 36