Replacing Hinges - Bosch Benchmark Series Service Manual

Induction slide-in ranges
Hide thumbs Also See for Benchmark Series:
Table of Contents

Advertisement

58300000187895 ARA EN A
NOTICE
It may be necessary to use a tool, such as a screwdriver, to gently
pry the upper part of the lever away from the housing. Take care to
avoid scratching the porcelain.
3. Partially close the oven door until it is open about 7" and
catches on the hinge-stop levers.
4. Using both hands, lift door upward and outward to disengage
the hinges from the hinge receiver slots.
5. Set the door aside on a protected flat surface.
To reinstall the door...
1. Hold the door firmly in both hands and position the hinges in
the hinge receivers, so that the slot in the base of the hinge (A)
engages with the hinge receiver (B).
Figure 5 Position the hinge in the hinge slot
2. Tilt the door inward and slide the hinges into place; the hinges
should catch and the door should remain in place.
3. Open door fully to expose the hinge levers and hinge receiver
slots.
4. Flip the right and left hinge levers forward until they are fully
closed.
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
MAY 2015
Figure 6 Closing hinge lever
5. Open and close the door carefully to confirm that the door is
installed correctly and securely, and does not appear to be
askew when closed.

7.1.3 Replacing Hinges

The doors on Bosch Benchmark series slide-in ranges are
QuietClose™ and operate using one dampen hinge and one spring
hinge. The hinges are offered in service kits which include both the
RH and LH hinges; always replace hinges in pairs.
NOTICE
The dampen hinge has a cylinder inside which holds oil that acts as
the dampening fluid and causes the soft-close effect. The oil must be
in the bottom of the cylinder. If the door does not close softly, allow
the hinge time to recover in the vertical position (door closed) for 15-
30 minutes, then re-test door operation. See bulletin packed with
hinge kits for more information.
To access the hinges...
1. Remove the door as described in the Removing and
Reinstalling the Door section.
2. With the porcelain-coated door liner up, remove the two
screws on each side of the door liner.
3. Remove the screws along the bottom of the door assembly.
1901 Main St ▪ Suite 600 ▪ Irvine, CA 92614
Service Manual for Bosch Benchmark Series Induction Slide-in Ranges
Page 14 of 36
800 944-2904

Hide quick links: