58300000187895 ARA EN A
3. Remove the screws surrounding the perimeter of the vented
rear housing cover, then grasping both sides, pull the cover
downward and away from the range.
NOTICE
The wire diagrams can be found in a plastic packet taped to the
vented rear housing cover.
4. Disconnect all harnesses from the control module, labeling
them as necessary.
Figure 26 Control module is visible after removing vented rear housing cover
5. Remove the screws securing the control module to the
mounting plate.
6. Install the new control module to the mounting plate and
reattach all harnesses securely.
7. Restore power to the unit and test operation.
8. Replace the vented rear housing cover and the wire diagram,
if it had been removed.
9. Slide the range back into the cutout, being sure to engage the
anti-tip bracket.
Copyright by BSH Home Appliances Corporation
This material is intended for the sole use of BSH authorized persons and may contain confidential and proprietary information. Any unauthorized review, use, copying, disclosure, or distribution in any format is prohibited.
MAY 2015
Whenever possible, conduct troubleshooting tests at the control
module, using the Service Guide as a reference.
7.11
The range uses a 2-speed 120VAC 28/41W cooling fan and a Hall
Effect sensor. If the sensor does not detect fan rotation, an error will
display.
To test the fan at the control module, check voltage across X105 / Pin
3 and neutral. There is also a Cooling Fan Relay Test available in
Service mode. See the Service Mode section for details.

7.11.1 Replacing the Cooling Fan

1. Remove power to the range.
2. Slide the range out of the cutout to allow access to the rear.
3. Remove the rear vent trim.
4. Remove the rear cooktop panel.
5. Remove the rear vented housing cover.
6. Remove the air box bracket.
7. Remove the fan motor cover.
Figure 27 View of fan motor cover (1) and air box bracket (2) surrounding cooling fan
8. Disconnect wires.
7. Remove screws securing the fan mounting bracket to the fan
and remove fan.