Download Print this page
Renfert Safety Burner eco 934 0100 Instruction Manual
Renfert Safety Burner eco 934 0100 Instruction Manual

Renfert Safety Burner eco 934 0100 Instruction Manual

Advertisement

Quick Links

Sicherheitsbrenner eco
Инструкция по эксплуатации
Instrucciones para el servicio
Instruction manual • Mode d´emploi
Istruzioni d'uso • Instrucciones para el servicio
Instruções de uso • Kullanım Kılavuzu
Инструкция по эксплуатации •
操作说明书 • 取扱説明書 • 사용 설명서 •
Made in Germany
Nr. 934 0100 / 935 0100
Bedienungsanleitung
Bedienungsanleitung
Instruction manual
Istruzioni d'uso
Mode d´emploi
사용 설명서
取扱説明書
‫تاميلعتلا ليلد‬
Ideas for dental technology
DE
EN
FR
IT
ES
PT
TR
RU
ZH
JA
KO
AR

Advertisement

loading

Summary of Contents for Renfert Safety Burner eco 934 0100

  • Page 1 Sicherheitsbrenner eco Nr. 934 0100 / 935 0100 Bedienungsanleitung Инструкция по эксплуатации Instrucciones para el servicio Bedienungsanleitung Instruction manual Istruzioni d’uso Mode d´emploi 사용 설명서 取扱説明書 Instruction manual • Mode d´emploi Istruzioni d’uso • Instrucciones para el servicio Instruções de uso • Kullanım Kılavuzu Инструкция...
  • Page 2 Safety Burner eco 934 0100 / 935 0100 ENGLISH 1. Introduction Description This safety burner eco, is a stable and reliable laboratory burner. As soon as the flame goes out, within 90 seconds a safety valve activates to create an automatic gas lock.
  • Page 3 Operation and maintenance of the unit may only be carried out by trained personnel. Disclaimer Renfert GmbH disclaims any responsibility for compensation or warranty if: ► the product is used for any purpose other than the intended use stipulated in the instructions.
  • Page 4: Product Description

    3. Product Description Component groups and functioning elements 1 Mixing tube 2 Sensor 3 Gas valve 4 Knurled nut 5 Hose spout 6 Actuation knob for ignition safeguard 7 Collection pan 8 Sensor holder 9 Clamping screw 10 Allen key Supplied in Delivery 1 Safety Burner eco 1 Instructions for Use...
  • Page 5: Cleaning & Maintenance

    Adjusting the flame Where? knurled nut (4) on the mixing tube. How? Soft flame: turn the knurled nut (4) in an upward direction (air supply reduced). Strong flame: the knurled nut (4) in a downward direction (air supply increased). The size of the flame can be slightly adjusted by opening / closing the gas valve (3). 6.
  • Page 6: Troubleshooting Guide

    Spare parts For the order numbers of consumables and spare parts please refer to the spare parts list at the end of this manual or find these on our website www.renfert.com. Maintenance The burner is maintenance-free. 7. Troubleshooting Guide...
  • Page 7: Technical Data

    When the equipment is used as intended and stipulated, Renfert warrants all parts of the unit with a guarantee of 3 years.

This manual is also suitable for:

Safety burner eco 935 0100