Page 1
High Tone Power Therapy Device ® HiToP Instruction manual gbo Medizintechnik AG Version 2.0...
Page 2
® HiToP The gbo Medizintechnik AG has taken care in preparation of this manual, but makes no expressed or implied warranty of any kind and assumes no responsibility for errors or omissions. All rights reserved. No part of this manual may be reproduced in any form or by any means (electronic, mechanical, or otherwise) without the prior written permission of the gbo Medizintechnik AG.
Page 3
Range between the upper and lower cut-off frequency. If the lower and upper cut- off frequency have got the same quarter tone, this range can be indicated in octaves. Softkey A softkey is a key with context-sensitive meaning. gbo Medizintechnik AG Version 2.0...
2.5.2 Deactivate intensity monitoring DESCRIPTION OF FUNCTION Description of the contents of display 3.1.1 General view 3.1.2 Detail view Operating notes 3.2.1 Menu key 3.2.2 Softkey 3.2.3 Channel keys 3.2.4 Intensity regulator 3.2.5 Modification knob gbo Medizintechnik AG Version 2.0...
Page 5
Disposal of the device and the accessories Cleaning, disinfection and care 8.3.1 Cleaning the Device 8.3.2 Cleaning the Elastic Straps 8.3.3 Cleaning the Electrodes 8.3.4 Disinfecting the Electrodes WARNINGS AND SAFETY PRECAUTIONS Contraindications EXPLANATION OF THE SIGNS USED gbo Medizintechnik AG Version 2.0...
Page 6
® HiToP TECHNICAL DATA ACCESSORIES INDEX gbo Medizintechnik AG Version 2.0...
A frequency travers of three octaves is realized. The frequency travers is realized with different speed (0.1 - 200 Hz). This therapy activates the metabolism in the body, thus having an effect of irritation. gbo Medizintechnik AG Version 2.0...
When turning the intensity regulator without activated channel. At the end of the faultless automatic check at the start of Triad gong operation. At the end of therapy. Table 2: Acoustical user support gbo Medizintechnik AG Version 2.0...
Module SimulFAM regulator Figure 1: Device view Application part ungrounded safety degree BF Caution! Observe the instruction for use ! Patient cable connection I;II;III and IV Figure 2: Device view from the right gbo Medizintechnik AG Version 2.0...
[Detail Display] it is possible to Softkey move to the detail view of the allocated channel. 15. At the end of the therapy the triad gong will sound. The current to the patient will be automatically reduced. gbo Medizintechnik AG Version 2.0...
Page 11
Here the frequency and the voltage for the chosen channels are shown. 15. At the end of the therapy the triad gong will sound. The current to the patient will be automatically reduced. gbo Medizintechnik AG Version 2.0...
Note! The conductivity of the electrodes is optimized by the use of a certain amount of graphite. Consequently, when using and cleaning the electrodes, black color may come off. 2.1.3 Disinfecting the Electrodes gbo Medizintechnik AG Version 2.0...
Page 13
We recommend Bacillol-AF for the disinfection of the electrodes. Note! The conductivity of the electrodes is optimized by the use of a certain amount of graphite. Consequently, when using and disinfecting the electrodes, black color may come off. gbo Medizintechnik AG Version 2.0...
Irrespective of the adjusted mains voltage, the device is appropriate for power frequencies of 48 to 62 Hz. Warning! To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. gbo Medizintechnik AG Version 2.0...
After switching on the device, an automatic check of all functions will be carried out. 2.3 Placing out of operation In order to disconnect the device just disconnect it from the mains power supply. No other measures are to be taken. gbo Medizintechnik AG Version 2.0...
During modification of the settings a return is always possible with the black [Return]. menu key The main menu can be chosen with the black menu key only, if the intensity is „0.0“ in all channels, i.e. no therapy is active any more. gbo Medizintechnik AG Version 2.0...
During the modification of the settings it is possible at any time to return with the black Menu key [Return]. If you have chosen the Effects menu, you get different settings in the basic menu, see chapter 2.4.4. *n.a.: these languages are not active on delivery. gbo Medizintechnik AG Version 2.0...
9. Exit the device setting menu by pressing the black [Return]. Menu key 10. On the display the Main menu appears again. 11. Exit the Main menu by pressing the black [Return]. Menu key 12. On the display the Overview window appears again. gbo Medizintechnik AG Version 2.0...
Page 19
9. Exit the device setting menu by pressing the black [Return]. Menu key 10. On the display the Main menu appears again. 11. Exit the Main menu by pressing the black [Return]. Menu key 12. On the display the Overview window appears again. gbo Medizintechnik AG Version 2.0...
If this message is displayed: Please check that the electrodes and cables of channel N have good contact, you should check the contact of the electrodes and the cables, resp., prior to setting the intensity anew. gbo Medizintechnik AG Version 2.0...
4. Please observe by all means the notice on the electrode position. (see chapter 6 Electrodes). 2.5.1 Intensity monitoring active We at gbo Medizintechnik AG have expanded the device software by a special intensity monitoring routine in order to get these application problems under control. This safety switching avoids an unintended high modification of the intensity of current and switches off the respective channel in such a case.
Menu Basic settings / Intensity monitoring or will automatically activated for all channels after each restart ! It is possible to call in the main menu with the black menu key only, if the intensity of all channels is „0.0“. gbo Medizintechnik AG Version 2.0...
100 Hz 12,5 V Display channel III not plugged no indicator on the display 30:22 3 Hz 0,0 V Ind. Menu channel IV plugged, but not active Dis. Ind. Menu Figure 5: Overview gbo Medizintechnik AG Version 2.0...
3.2.1 Menu key Menu Use the black to call up the main menu (see chapter 2.4.1 Menu key: Menu key The main menu) Figure 7: Black Menu key on the upper right of the display. gbo Medizintechnik AG Version 2.0...
„0.0“. Control the current indication on the display. The main menu can only be called up with the black menu key, if the intensity of all channels has been set to „0.0“ . gbo Medizintechnik AG Version 2.0...
If one surge parameter is turned to „0“ seconds, also the remaining surge parameters are adjusted to „0“ automatically. If one surge parameter is increase once again, the remaining surge parameter are automatically set to „1“ second. gbo Medizintechnik AG Version 2.0...
At the end of the therapy time the stimulation current to the patient will automatically be reduced: The triad gong will sound (see also Table 2: Acoustical user support). The automatically reverts to „0.0“-after switching off the stimulation Intensity regulator current to the patient. gbo Medizintechnik AG Version 2.0...
CD out. Function key Stop Note! If despite the volume regulation on the headphones there is no reproduction, control the volume regulator on the CD drive assembly. gbo Medizintechnik AG Version 2.0...
10. Detail view is shown on the right side of the display. Activate it by pressing the respective Softkey 11. In this window the current, resistance, actual power, and released energy are shown additionally. 12. You return to the general window by pressing one of the Channel keys gbo Medizintechnik AG Version 2.0...
7. Within 20 seconds after having activated the intensity regulator, the program returns to the overview window. 8. Here the frequency and the voltage for the chosen channels are shown. 9. On the right side of the display [Detail view] is shown. Activate it by pressing the respective Softkey gbo Medizintechnik AG Version 2.0...
Continue. 4. Confirm by pressing the white Softkey 5. The list of indications for the selected group appears on the display. 6. Move the scroll bar/cursor with the to the desired indication. Modification knob gbo Medizintechnik AG Version 2.0...
Page 32
1st current type of 3 8192 Hz P 1/3 13:25 100 Hz 12,5 V Detail Anzeige 30:22 3 Hz 0,0 V Ind. Menü actual current type Figure 21: Therapy program in the indication menu gbo Medizintechnik AG Version 2.0...
In the detail window current, resistance, power and energy are shown additionally. The therapy time cannot be changed during treatment. If only one patient cable is plugged to the unit, you will get directly to the detail window. gbo Medizintechnik AG Version 2.0...
As this program will only free but not burn the freed fatty cells it is recommended to follow it up with physical exercise. The program length is pre-set to 30 minutes but can be changed by the user. gbo Medizintechnik AG Version 2.0...
Page 35
3 - 10 Hz. This will result in a vibration or shaking of the muscle and is therefor called Shaking- massage. The program length is pre-set to 30 minutes but can be changed by the user. gbo Medizintechnik AG Version 2.0...
Page 36
(contraction) and 20 s pause. A important innovation that gbo HighTone Therapy adds to the muscle training is that we can use a sub- threshold 32 kHz current (i.e. the user does not feel it) during the pauses to alleviate the metabolism and thereby greatly improve the muscles ability to be supplied with new nutrients and to get rid of waste products.
Page 37
Thie program is used for pain relief at diabetic polyneuropathies. Caused by muscle activation, the metabolism is improved, thus improving the sensibility to insulin. The program length is pre-set to 60 minutes but can be changed by the user. gbo Medizintechnik AG Version 2.0...
Page 38
0,1 – 200 Hz 30 minutes pre-set adjustment 1s /Freq. Grundeinstellung 18 Diab. PNP 20 Hz 60 Minuten diabetic polyneuropathies 3s / 3s / 3s Adjustment phase 20 seconds Table 6: Programs of the Effects menu gbo Medizintechnik AG Version 2.0...
5. You are in the Menu Program patient unit Therapy I SimulFAM Menü Return Patient unit Confirm Program Therapy I SimulFAM i Change Treatment time 60 min Number of treatments ® Figure 23: Programming of patient unit with SimulFAM gbo Medizintechnik AG Version 2.0...
Therapy II: Menü Return Patient unit Select Program Therapy II without Channel I Channel II Channel III Channel IV SimulFAM i SimulFAM X Nerve block Figure 24: Menu Programming of patient unit / Therapy II gbo Medizintechnik AG Version 2.0...
7. Upon correct transmission the following note will be shown on the display: Menü Patient unit Continue Program Therapy I SimulFAM i Successful data transmission Figure 26: Menu Programming of patient unit / Successful data transmission gbo Medizintechnik AG Version 2.0...
4. You move to the display of the preset type of current of the respective channel. ® 5.2.3 Selection SimulFAM ® 1. Move with the Modification knob to SimulFAM 2. The selection is shown inversely. 3. Press the [Select]. Softkey gbo Medizintechnik AG Version 2.0...
Page 43
Therapy II and move to Softkey ] and you will exit d display Therapy III or exit display Therapy III and move to the transmission window (see Figure 25: Menu Programming of patient unit / start). gbo Medizintechnik AG Version 2.0...
Therapy II to move to display Softkey and you exit the d Therapy III or exit display Therapy III to move to the transmission start window (see Figure 25: Menu Programming of patient unit / start). gbo Medizintechnik AG Version 2.0...
As a possible consequence the adhesive electrodes get warm during the therapy and might even heat up to a temperature that causes burns with the patient. To avoid such situations gbo has removed the adhesive electrodes from the standard accessory set ®...
Otherwise there can occur skin redness, and sometimes even burns. It is recommended not to exceed the current density of 2 mA/cm for all electrodes. During the therapy the patient must take off jewelry and glasses. gbo Medizintechnik AG Version 2.0...
This note is only applicable for current circuits that overlap in a significantly large area. Of cause local therapies of small body regions, e.g. the knee, during a whole-body treatment are not concerned by this. gbo Medizintechnik AG Version 2.0...
Please check that the electrodes of channel N have good contact. Short circuit in channel . . .! Suggestion: This means that the patient circuit has been interrupted. Check the electrodes, cables and connections. gbo Medizintechnik AG Version 2.0...
The device must be returned to the manufacturer for disposal. The manufacturer is committed to guarantee the disposal of all devices marketed. This is also indicated by the WEEE sign (crossed out waste container). gbo Medizintechnik AG Version 2.0...
We recommend Bacillol-AF for the disinfection of the electrodes. Note! The conductivity of the electrodes is optimized by the use of a certain amount of graphite. Consequently, when using and disinfecting the electrodes, black color may come off. gbo Medizintechnik AG Version 2.0...
Application of electrodes near the thorax may increase the risk of cardiac fibrillation. In case of any visible failures please contact immediately gbo Medizintechnik AG or one of the service agencies authorized by gbo Medizintechnik AG. gbo Medizintechnik AG...
The above list is not exhaustive. In individual cases the attending doctor should decide on contraindications and criteria for the treatment. Note! Patients with varicose veins, metallic implants and endoprothesis may be treated with ® HiToP Therapy. gbo Medizintechnik AG Version 2.0...
Caution ! Observe the instructions for use ! Application part ungrounded, protection degree Type BF This product complies with WEEE Directive 2002/96/EG (waste electrical and electronic equipment). Separate collection for electrical and electronic equipment. gbo Medizintechnik AG Version 2.0...
Relative humidity < 90 %, none condensing Current types: Sinusoidal currents of 4096 - 32768 Hz Modulation frequency currents of 0.1 Hz - 200 Hz gbo Medizintechnik AG reserves the right to modify the design and specification without prior notice. gbo Medizintechnik AG Version 2.0...
Headphones for integrated CD player 017-0-0039 ® UNICAR 1000 device cart (basic rack) and 014-0-1000 and device porter (large) 014-0-1020 Note! Use gbo original accessories only to guarantee the safe function of the unit. gbo Medizintechnik AG Version 2.0...
Page 56
You find more EMC-comments in the chapter “Warnings and Safety Precautions” of this manual as well as in the Technical Information on the next two pages. gbo Medizintechnik AG Version 2.0...
Page 57
IEC 61000-4-8 location in a typical commercial or hospital environment. Note: U is the a.c. mains voltage prior to application of the test level. gbo Medizintechnik AG Version 2.0...
Page 58
Separation distance according to the tranmission frequency (m) transmitter (W) 150 kHz to 80 MHz 80 MHz to 800 MHz 800 MHz to 2,5 GHz d=1,2P d=1,2P d=2,3P 0,01 0,12 0,12 0,23 0,38 0,38 0,73 gbo Medizintechnik AG Version 2.0...
Page 59
Transport of the device 12 Indication menu 29 Voltage selector 13 Keys and Regulator Menu key 22 Softkey 23 Channel keys 23 Warning 12, 44, 49 Modification knob 24 Warnings 12, 49 LED 8 gbo Medizintechnik AG Version 2.0...
Need help?
Do you have a question about the HiToP 184 and is the answer not in the manual?
Questions and answers
Где можно досканально научиться работать на аппарате Hi top 184
You can learn to operate the gbo HiToP 184 machine in detail by referring to its instruction manual. The manual provides descriptions, explanations, warnings, safety precautions, and step-by-step instructions for using the device.
This answer is automatically generated