SICK AS30 Prime Edge Operating Instructions Manual

SICK AS30 Prime Edge Operating Instructions Manual

Array sensor
Hide thumbs Also See for AS30 Prime Edge:

Advertisement

O P E R A T I N G I N S T R U C T I O N S
AS30 Prime - Edge
Array Sensor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AS30 Prime Edge and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SICK AS30 Prime Edge

  • Page 1 O P E R A T I N G I N S T R U C T I O N S AS30 Prime - Edge Array Sensor...
  • Page 2 This work is protected by copyright. Any rights derived from the copyright shall be reserved for SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Any modifica‐...
  • Page 3: Table Of Contents

    Additional settings via SOPAS..............Troubleshooting................. 37 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 4 13.2 Certification according to UL60947-5-2..........13.3 Licences....................O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 5: About This Document

    Commissioning is described using one particular device variant as an example. Simplified device designation in the document In the following, the sensor is referred to in simplified form as “AS30 Prime Edge” or “device”. Explanation of symbols Warnings and important information in this document are labeled with symbols. The warnings are introduced by signal words that indicate the extent of the danger.
  • Page 6: Further Information

    Before calling, make a note of all type label data such as type code, serial number, etc., to ensure faster processing. O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 7: Safety Information

    The system designer must provide measures to ensure the safety of persons and sys‐ tems in accordance with the legal guidelines. SICK AG assumes no liability for losses or damage arising from the use of the product, either directly or indirectly. This applies in particular to use of the product that does not conform to its intended purpose and is not described in this documentation.
  • Page 8: Requirements For Skilled Persons And Operating Personnel

    SICK AG. O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 9: Product Description

    1 = LED +3 buttons 2 = TFT +3 buttons 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 10: Product Features And Functions

    The array sensors can be used in any application that requires the detection of one (AS30 Prime Edge Mode) or two edges (AS30 Prime Width Mode) based on a clear con‐ trast difference. With two edge devices, the edge distance (width) or center point (cen‐...
  • Page 11 Detection and positioning of an edge for highly accurate positioning (accurate posi‐ tion value) 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 12: Mounting

    • Shock and vibration resistant mounting. O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 13: Mounting The Device

    Observe the sensing range variation and tolerances. In the case of high-gloss materials, angle the AS30 Prime Edge at > 8° at the side for better detection reliability.
  • Page 14: Electrical Installation

    If these instructions are not complied with, the IP enclosure rating for the device is not guaranteed! O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 15: Note On The Swivel Connector

    To ensure protection against short-circuits/overload in the customer’s supply cables, the wire cross-sections used must be appropriately selected and protected. 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 16: Wiring The Interfaces

    ‒ (M) ‒ (M) ‒ (M) O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 17 ELECTRICAL INSTALLATION 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 18: Commissioning

    O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 19: Operation

    The driver for this product can be found at www.sick.com/AS30. This chapter will first describe how to operate the sensor from the control panel. Some additional settings that are not available from the control panel are described in see "Additional settings via...
  • Page 20: Navigation Tree, General

    The sensor shows the start screen in RUN mode O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 21 Figure 4: Menu tree with Teach-In and Settings / Operating Mode / Sensitivity menus 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 22 Figure 5: Menu tree with Settings / Teach Tolerance / Reading Direction / Background menus O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 23 Figure 6: Menu tree with Settings / Pin 5 / Display Direction menu 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 24 Figure 7: Menu tree with Settings / Teach Tolerance / Job Assurance menus O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 25: Activating Or Deactivating The Pushbutton Lock

    Press and hold the + pushbutton > 10 s – Pushbutton lock deactivated 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 26: Resetting The Device (Factory Setting)

    Confirm the selection with the SET pushbutton – The display shows SAVED O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 27: Area Teach

    Ql2 switching outputs can be defined in the Area menu. The edges must be located in the field of view. 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 28 Save the setting with the SET pushbutton – The display shows SAVED O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 29: Additional Settings

    In the Settings menu Select the Sensitivity menu with the +/- pushbutton 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 30 The display shows SAVED 7.8.3 Setting reading direction The AS30 Prime Edge offers 2 reading directions for the sensor. The millimeter values of the edge position are output in the configured direction. The analog output on pin 2 switches accordingly.
  • Page 31 If the sensor is mounted at a 180° rotated position, the display can be rotated accord‐ ingly. 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 32 The active parameters are overwritten. Figure 18: Store Job menu O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 33: Additional Settings Via Sopas

    The SOPAS ET software can be downloaded from the following link:https:// www.sick.com/de/en/sopas-engineering-tool-2018/p/p367244 The driver for this product can be found at www.sick.com/AS30. 7.9.1 Setting up the sensor The sensor can be set up with the wizard. The alignment of the sensor (sensing distance, mounting angle) is optimized using the supplied alignment aid.
  • Page 34 7.9.2 Selecting the operating mode The operating mode can be selected in the next step. The AS30 Prime Edge sensor has 2 possible operating modes: • Edge Detection The edge selected in the Teach-In Edges menu is detected within tolerances val‐...
  • Page 35 "Selection of reflector / sensing mode", page 30 • Reading direction The AS30 Prime Edge offers 2 reading directions for the sensor. The edge position values are outputted in the configured direction. The analog output on pin 2 switches accordingly. The options are...
  • Page 36 Configuring field of view • Configuring the analog output O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 37: Troubleshooting

    8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 38: Maintenance

    Only use cleaning agents suitable for the lens material. NOTE Static charge may cause dust particles to stick to the light emission window. This effect can be avoided by using an anti-static glass cleaner in combination with the SICK lens cloth (can be obtained from www.sick.com). NOTE If the light emission window is scratched or damaged (cracked or broken), the device must be replaced.
  • Page 39 In order to ensure that the heat produced by the internal power loss is adequately dissi‐ pated, the housing surface must be kept clean. 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge...
  • Page 40: Decommissioning

    As it is categorized as electronic waste, the device must never be disposed of with household waste! 10.2 Returning devices Do not dispatch devices to the SICK Service department without consultation. NOTE To enable efficient processing and allow us to determine the cause quickly, please include the following when making a return: Details of the contact person ■...
  • Page 41: Technical Data

    Ambient temperature, operation –10 °C … +55 °C 8023520/2019-07-15 | SICK O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge Subject to change without notice...
  • Page 42: Dimensional Drawing

    Without load Sum current of all outputs Male connector In = 2A 11.2 Dimensional drawing AS30 Prime Edge TW 25 12,9 Optical axis Field of view, 30 mm Fixing hole, 4.1 mm M12 device connection, can be rotated by 180°...
  • Page 43 TECHNICAL DATA AS30 Prime Edge TW 100 52.5 99.9 (2.07) (3.93) 48.3 (1.22) (1.9) (1.26) 11.2 (0.44) (0.22) (0.35) Optical axis Field of view 50 mm Fixing hole, 4.1 mm M12 device connection, can be rotated by 180° 8023520/2019-07-15 | SICK...
  • Page 44: Accessories

    Accessories can be found on the online product page at: www.sick.com/AS30 O P E R A T I N G I N S T R U C T I O N S | AS30 Prime - Edge 8023520/2019-07-15 | SICK Subject to change without notice...
  • Page 45: Annex

    13.3 Licences SICK uses open-source software. This software is licensed by the rights holders using the following licenses among others: the free licenses GNU General Public License (GPL Version2, GPL Version3) and GNU Lesser General Public License (LGPL), the MIT license, zLib license, and the licenses derived from the BSD license.
  • Page 46 E-Mail office@sick.com.gr E-Mail info@sick.ru Vietnam Hong Kong Singapore Phone +65 6744 3732 Phone +852 2153 6300 Phone +65 6744 3732 E-Mail sales.gsg@sick.com E-Mail ghk@sick.com.hk E-Mail sales.gsg@sick.com Detailed addresses and further locations at www.sick.com SICK AG | Waldkirch | Germany | www.sick.com...

This manual is also suitable for:

As30 prime widthAs30 prime - edge

Table of Contents