Electric Motor - MULTIQUIP Whiteman WM45H Operation And Parts Manual

Plaster/mortar mixer
Hide thumbs Also See for Whiteman WM45H:
Table of Contents

Advertisement

Electric Motor

For maintenance care and operation of the electric motor,
refer to your electric motor instruction booklet furnished
with the motor.
Protect the electric motor from dust as much as possible
and keep ventilating openings clean.
The electric motor used in this mixer is a single-phase 1.0
HP motor. The input voltage requirement for this motor is
either 115 or 230 VAC only.
Electric Motor Connection
A 12 inch electrical cable (Figure 4) with a pigtail at one end
is provided with the electrical motor for hookup to a power
source. Table 4. shows the required NEMA connector for
the desired motor horsepower rating. In addition, Table 3
also shows the matching NEMA approved connector for
the required extension cord.
ALWAYS, make certain that the power source required
for the electric motor is correct and always use the correct
NEMA configuration plug. Failure to supply the correct
voltage to the motor can severely damage the motor.
The motor supplied is wired for 115 VAC grounded
operation. Make certain that the correct size grounded
(3-wires) extension cord is used. See Table .
Motors can burn out when the line voltage falls 10% below
the voltage rating of the motor. Failure to use proper voltage
will cause the motor to overheat and actuate the overload
switch.
If overload protection should activate because of improper
voltage or any other malfunction, turn the main switch on
the motor to the "OFF" position and correct the problem,
press the reset switch button, and turn the main switch to
the "ON" position.
WM45H/E PLASTER MORTAR MIXER • OPERATION AND PARTS MANUAL — REV. #1 (09/09/19) — PAGE 15
Figure 4. Single-Phase Electric Motor
18-Inch Pigtail Cable
ELECTRIC MOTOR
Electric Motor Voltage Switch
1. ALWAYS make certain the electric motor switch
is "OFF" (Figure 4)and the power cord has been
disconnected from the power source.
2. Remove the voltage lock-out bolt. Change the position
of the voltage change toggle switch from 115 VAC
to 230 VAC. The mixer is factory wired for 115 VAC
operation.
3. Re-install voltage lock-out bolt.
4. Important!, when changing the electric motor input
voltage from 115 to 230 VAC the plug on the motor
power cord must also be changed. See Table 5.
Table 4. Electric Motor Wiring Information
115-230 VAC Single Phase
HP/Voltage
NEMA Plug
1.0/115VAC
P/N EM 940537
1.0/230VAC
P/N EM 940537
Table 5. Recommended Extension Cord Sizes
Model
Motor Voltage
115
WM45E
1 HP
230
NOTICE
ALWAYS make certain that the power source required
for the electric motor is correct and always use the
correct NEMA configuration plug. Failure to supply
the correct voltage to the motor can severely damage
the motor.
Mating NEMA
Receptacle
L5-20P
SAE 10W-30
L5-20P
SAE 10W-30/20
50 ft.
75 ft.
100 ft.
(15 m)
(23 m)
(30 m)
No. 12
No. 10
No. 8
No. 14
No. 12
No. 12
200 ft.
(61m)
No. 6
No. 8