The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
The following pharmaceutical reduction claims have not been certified by NSF International or the state of California.
Claims tested and verified by independent laboratory
Contaminant
Average
Reduction
Influent
Atenolol
978 ng/L
907 ng/l
885 ng/L
Progesterone
1097 ng/L
Trimethoprim
415 ng/L
Application Guidelines/Water Supply Parameters
0.5 gpm (21.9 lpm)
Water Supply
Potable Water
NOTE While the testing was performed under standard laboratory
conditions, actual performance may vary. Contaminant reduction
testing is conducted every five years by certifying agency to
maintain certification.
elements please call 1.877.959.8688 or visit our website at
www.geapplianceparts.com.
To reduce the risk associated with ingestion of contaminants
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before and
after the system. Systems certified for cyst reduction may be
used on disinfected water that may contain filterable cysts.
claims specified on the performance data sheet.
REPLACEMENT
ELEMENT
49-60647-5
NSF specified
Challenge
Avg %
Concentration
Reduction
N/A
99.5
N/A
99.4
N/A
94.1
N/A
99.5
N/A
99.5
Average
Max Permissible
Product Water
Product Water
Concentration
Concentration
5.0 ng/L
N/A
5.4 ng/L
N/A
52.3 ng/L
N/A
5.0 ng/L
N/A
2.0 ng/L
N/A
Water Pressure
40-120 psi (276-827 kPa)
Water Temperature
NOTICE
To reduce the risk associated with property damage due to
water leakage
Read and follow use instructions before installation and use of
this system.
MUST comply with all state and local
plumbing codes.
Do not
your water pressure exceeds 80 psi (552 kPa), you must install
a pressure-limiting valve. Contact a plumbing professional if you
are uncertain how to check your water pressure.
Do not
water hammer conditions exist you must install a water hammer
arrester. Contact a plumbing professional if you are uncertain
how to check for this condition.
Do not install on hot water supply lines. The maximum operating
Protect filter from free ing.
The disposable filter cartridge should be replaced every 6
months at the rated capacity, or sooner if a noticeable reduction
in flow rate occurs.
NSF Reduction
NSF
Requirements
Test Report
N/A
J-00121587
N/A
J-00121587
N/A
J-00121588
N/A
J-00121589
N/A
J-00121587