Process/Polarity Table; Changing Polarity; Installing Wire Spool And Adjusting Hub Tension - Hobart Welding Products Handler 125 Owner's Manual

Table of Contents

Advertisement

5-3. Process/Polarity Table

Process
FCAW − Self-shielding wire − no
shielding gas
GMAW − Solid wire with shielding gas

5-4. Changing Polarity

1
FCAW

5-5. Installing Wire Spool And Adjusting Hub Tension

Installing 4 in. (102 mm) And 8 in. (203 mm) Wire Spools
Polarity
DCEN − Straight Polarity
Gun cable is connected to the
negative (−) output
DCEP − Reverse Polarity
Gun cable is connected to the
positive (+) output
Cable Connections
Cable To Gun
Work cable is connected to the positive
(+) output
Work cable is connected to the nega-
tive (-) output
1
2
Always read and follow wire
manufacturer's recommended po-
larity, and see Section 5-3.
Close door.
2
GMAW
When a slight force is needed
to turn spool, tension is set.
Cable To Work Clamp
Lead Connections For Direct
Current Electrode Negative
(DCEN)
Lead Connections For Direct
Current Electrode Positive
(DCEP)
Ref. 210428
161072 / 803012
OM-283007 Page 13