Page 1
311833F Designed for low pressure, medium volume circulation of finishing materials. For professional use only. Models P06DCK, P06ECK, P06LCK, P06MCK, P06DSG, P06ESG, P06LSG, P06MSG 620 psi (4.2 MPa, 42.7 bar) Maximum Working Pressure 100 psi (0.69 MPa, 6.9 bar) Maximum Air Inlet Pressure Models P10DCK, P10ECK, P10LCK, P10MCK, P10LCS 1180 psi (8.14 MPa, 81.4 bar) Maximum Working Pressure...
® Pumps with NXT Air Motors Part No. Matrix ® Pumps with NXT Air Motors Part No. Matrix Check your pump’s identification plate (ID) for the 6-digit part number of your pump. Use the following matrix to define the construction of your pump, based on the six digits. For example, Pump Part No. P 0 6 M S G represents ™...
Warnings Warnings The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.
Page 5
Warnings WARNING PRESSURIZED EQUIPMENT HAZARD Fluid from the gun/dispense valve, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment.
Installation Installation Grounding Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity. To maintain grounding continuity when flushing or The equipment must be grounded.
Installation • Fluid drain valve: required in your system, to relieve fluid pressure in the hose and gun. • Fluid shutoff valve: shuts off fluid flow. • Fluid pressure regulator: for more precise adjust- ment of the fluid pressure. • Gun or valve: to dispense fluid.
Operation Operation Pressure Relief Procedure 1. Engage trigger lock. 2. Close the bleed-type master air valve. 3. Disengage the trigger lock. 4. Hold a metal part of the gun firmly to a grounded metal pail. Trigger the gun to relieve pressure. 5.
Maintenance Maintenance Shutdown To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pres- sure Relief Procedure on page 8. To reduce risk of static sparking or splashing in the eyes To reduce the risk of serious injury whenever you are or on the skin, relieve the pressure and remove the instructed to relieve pressure, always follow the Pres- spray tip before flushing.
Troubleshooting Troubleshooting 2. Check all possible problems and solutions before disassembling pump. To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pres- sure Relief Procedure on page 8. Never operate the pump with the air motor shield removed.
Repair Repair Required Tools 5. Hold the tie rod flats with a wrench to keep the rods (6) from turning. Unscrew the nuts (7). Remove the lower (2). • Set of socket wrenches • Set of adjustable wrenches 6. To service the lower, refer to manual 311716 or •...
7. Reconnect all hoses. Reconnect the ground wire if it (4) are in place on the displacement rod. was disconnected. Fill the wet-cup 1/3 full of Graco 4. Use at least two people to hold the lower while Throat Seal Liquid or compatible solvent.
Pump Mounting Hole Diagram Pump Mounting Hole Diagram NXT Model 3400 Four 3/8-16 Mounting Holes 6.186 in. (157 mm) Six 5/8-11 Tie Rod Holes 6.186 in. TI8070A (157 mm) NXT Model 6500 Four 3/8-16 Mounting Holes 101.6 mm (4.0 in.) 6.180 in.
Technical Data Technical Data Maximum Maximum Fluid Flow at Working Pressure Air Input Pressure 60 cycles per minute Model psi (MPa, bar) psi (MPa, bar) Air Consumption gpm (lpm) All P06 _ _ _ Models 620 (4.2, 42) 100 (0.69, 6.9) 17.4 (65.8) See Performance Chart All P10 _ _ _ Models...
Page 19
Technical Data 0.7 MPa, 7 bar (100 psi) air pressure or 10.5 MPa, 105 bar (1500 psi) hydraulic oil pressure 0.5 MPa, 4.9 bar (70 psi) air pressure or 7.5 MPa, 75 bar (1050 psi) hydraulic oil pressure 0.3 MPa, 2.8 bar (40 psi) air pressure or 4.2 MPa, 42 bar (600 psi) hydraulic oil pressure Test Fluid: No.
With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective.
Need help?