Analog power ......................................... 100 mW max
+15 V .............................................. 3.2 mA max
–15 V............................................... 3.2 mA max
Digital power (+5 V).............................. 0.0 mW
Operating voltage range
+15 V .............................................. ±10%
–15 V............................................... ±10%
Dimensions............................................. 8.89 cm × 2.92 cm × 1.85 cm
I/O connectors ........................................ One 20-pin right-angle
Wire gauge range ................................... 28 to 16 AWG
Maximum working voltage refers to the signal voltage (I × 249 Ω) plus the
common-mode voltage.
Channel-to-earth..................................... ±15 V, Installation Category I
Channel-to-channel ................................ ±15 V, Installation Category I
Operating temperature............................ 0 to 50 °C
Storage temperature ............................... –20 to 70 °C
Humidity ................................................ 10 to 90% RH, noncondensing
Maximum altitude .................................. 2,000 m
Pollution Degree (indoor use only) ........ 2