The SCC-AI Series isolated analog input modules can extract a relatively
low-amplitude input signal from a high-common-mode voltage so the
E/M Series DAQ device can measure the input signal. They also can
amplify and filter the input signal, resulting in higher measurement
resolution and accuracy.
SCC-AI Series modules are available in a range of gains from 0.2 to 200.
They contain lowpass filters of either 10 kHz or 4 Hz bandwidth. Table 1
gives the gain and bandwidth for each module.
Table 1. SCC-AI Module Input/Output Range, Gain, and Bandwidth
Model
Input Range
SCC-AI01
±42 V
pk
SCC-AI02
±20 V
SCC-AI03
±10 V
SCC-AI04
±5 V
SCC-AI05
±1 V
SCC-AI06
±100 mV
SCC-AI07
±50 mV
SCC-AI13
±10 V
SCC-AI14
±5 V
Output Range
/ VDC
±8.4 V
±10 V
±10 V
±10 V
±10 V
±10 V
±10 V
±10 V
±10 V
Gain
Bandwidth
0.2
10 kHz
0.5
10 kHz
1
10 kHz
2
10 kHz
10
10 kHz
100
10 kHz
200
10 kHz
1
4 Hz
2
4 Hz

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SCC-AI Series and is the answer not in the manual?

Questions and answers

Summary of Contents for National Instruments SCC-AI Series

  • Page 1 SCC-AI Series modules are available in a range of gains from 0.2 to 200. They contain lowpass filters of either 10 kHz or 4 Hz bandwidth. Table 1 gives the gain and bandwidth for each module.
  • Page 2 SC-2345 refers to both the SC-2345 connector block and the SC-2345 configurable connector. SCC refers to any SCC series signal conditioning module. SCC-AI SCC-AI refers to any isolated analog input module in the SCC-AI Series unless otherwise noted. SCC-AI Series Isolated Analog Input Modules User Guide ni.com...
  • Page 3: What You Need To Get Started

    Quick Reference Label ❑ Software – The latest version of NI-DAQmx ❑ Documentation – SCC-AI Series Isolated Analog Input Modules User Guide – SC-2345/2350 User Manual – SCC-68 User Guide – SCC Quick Start Guide – Read Me First: Safety and Radio-Frequency Interference –...
  • Page 4: Device Specific Information

    Sockets J9 to J16 of the SC-2345 are also available for digital input/output (DIO) conditioning or control. Refer to the SC-2345/2350 User Manual for more information about configuring, connecting, and installing SCC modules. SCC-AI Series Isolated Analog Input Modules User Guide ni.com...
  • Page 5: Connecting The Input Signals

    1 and 3, to AI SENSE on the SC-2345/2350 terminal block or AI GND on the SC-68, through a 10 kΩ to 100 kΩ resistor. Figure 2 shows a floating signal connection on one channel of the SCC-AI. © National Instruments Corporation SCC-AI Series Isolated Analog Input Modules User Guide...
  • Page 6 Figure 3. Ground-Referenced Signal Connection for the SCC-AI with High Common-Mode Voltage (One Channel) For information about how to configure the SCC-AI module using NI-DAQmx, refer to the SCC Quick Start Guide. SCC-AI Series Isolated Analog Input Modules User Guide ni.com...
  • Page 7: Gain Adjustment

    SCC-AI. Apply the voltage given in Table 2 that corresponds to the SCC-AI module. For example, if you have an SCC-AI03, you must apply 8 VDC. © National Instruments Corporation SCC-AI Series Isolated Analog Input Modules User Guide...
  • Page 8: Offset Voltage Adjustment

    SCC-AI, labeled Offset. Turn the trimpot clockwise to increase the offset. Repeat steps 4 and 5 until the voltage read in step 4 equals 0.00 V. SCC-AI Series Isolated Analog Input Modules User Guide ni.com...
  • Page 9: Specifications

    AI does not provide isolation between the two channels of the module. For more information, refer to the Connecting the Input Signals section. This specification is calculated relative to the input range of the module. © National Instruments Corporation SCC-AI Series Isolated Analog Input Modules User Guide...
  • Page 10: Power Requirement

    This device is rated for Measurement Category I and is intended to carry signal Caution voltages no greater than 42.4 V or 60 VDC. Do not use this device for connection to peak signals or for measurements within Categories II, III, or IV. SCC-AI Series Isolated Analog Input Modules User Guide ni.com...
  • Page 11: Isolation Voltage

    ICES-001: Class A emissions The SCC AI does not provide isolation between the two channels of the module. For more information, refer to the Connecting the Input Signals section. © National Instruments Corporation SCC-AI Series Isolated Analog Input Modules User Guide...
  • Page 12: Online Product Certification

    Waste Electrical and Electronic Equipment (WEEE) EU Customers At the end of the life cycle, all products must be sent to a WEEE recycling center. For more information about WEEE recycling centers and National Instruments WEEE initiatives, visit ni.com/environment/weee RoHS...
  • Page 13 ±15 V supplies and REF 5 V. AI GND and A GND connect to the SC-2345/2350 at the SCC-PWR connector. GND is the reference for the +5 V supply. © National Instruments Corporation SCC-AI Series Isolated Analog Input Modules User Guide...
  • Page 14 — — National Instruments, NI, ni.com, and LabVIEW are trademarks of National Instruments Corporation. Refer to the Terms of Use section on ni.com/legal for more information about National Instruments trademarks. Other product and company names mentioned herein are trademarks or trade names of their respective companies.