Siemens SIMATIC S7-1500 Manual page 53

Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Electrical isolation
Electrical isolation, channels
Between channels
Between channels and backplane bus
Insulation
Insulation test voltage
Standards, approvals, certificates
Maximum achievable safety class in safety mode
Performance level according to EN ISO 13849-
1:2008
SIL according to IEC 61508
Low demand mode: PFDavg according to SIL3
High demand/continuous mode: PFH according to
SIL3
Environmental conditions
Ambient temperature in operation
Horizontal installation, min.
Horizontal installation, max.
Vertical installation, min.
Vertical installation, max.
Dimensions
Width
Height
Depth
Weights
Weight, approx.
Note
To reach the maximum cable length, it may be necessary to increase the settings for
maximum readback time switch on test or maximum read-back time dark test.
We also recommend a more detailed consideration of the boundary conditions, such as
EMC, cables used, cable guide, etc.
Dimension drawing
See system manual S7-1500 Automation System
(http://support.automation.siemens.com/WW/view/en/59191792).
Digital output module F-DQ 8x24VDC/2A PPM (6ES7526-2BF00-0AB0)
Manual, 01/2016, A5E03858037-AA
Technical specifications
6ES7526-2BF00-0AB0
No
Yes
707 VDC (type test)
PLe
SIL 3
< 6.00E-05
< 2.00E-09 1/h
0 °C
60 °C
0 °C
40 °C
35 mm
147 mm
129 mm
300 g
53