DISPLAY TEXT
BACNET (cont)
COV OAT
DEVICE RARH
OBJECT ID RARH
COV RARH
DEVICE RAT
OBJECT ID RAT
COV RAT
DEVICE SPT
OBJECT ID SPT
COV SPT
LOCAL_SHEDL_EDIT
SYSTEM TOUCH
DEVICE INSTANCE
POLLING RATE
SPACE TEMP AI
SPACE RH AI
ZS SENSOR CFG
ZS1 ADDRESS
ZS2 ADDRESS
ZS3 ADDRESS
ZS4 ADDRESS
ZS5 ADDRESS
ZS POLL RATE
ZS UNIT
ZS FRC UNOC ENBL
ZS FRC UNOC DELAY
ZS TLO CONT ENBL
TLO SET DURING OC
ZS UI MODE
NETWORK CHKLIST
DISPLAY SETTINGS
METRIC DISPLAY
LANGUAGE
CONTRAST ADJUST
PASSWORD ENABLE?
VIEW USER PASSWORD
CHANGE USER PASSWORD
QUICK SETUP CONFIG
TIME
DATE
STARTUP DELAY
UNIT CONTROL TYPE
THERMOSTAT TYPE
DIRTY FILTER TIME
HEATING STAGE QTY
VENT METHOD
FREE COOL MAX OAT
FIRE SHUTDOWN SW
QUICK SET CHKLIST
Settings - - Main Menu Layout (cont)
EXPANDED DISPLAY TEXT
BACnet network configuration menu
Change of value for OAT
BACnet device for RARH
Object instance for RARH
Change of value for RARH
BACnet device for RAT
Object instance for RAT
Change of value for RAT
BACnet device for SPT
Object instance for SPT
Change of value for SPT
Allow Local Sched Edit
System Touch Menu
System Touch Device Inst
System Touch Poll Rate
System Touch AI for SPT
System Touch AI for SPRH
ZS Sensor Configuration
Zone Sensor 1 Address
Zone Sensor 2 Address
Zone sensor 3 address
Zone sensor 4 address
Zone sensor 5 address
Zone sensor poll rate
Zone sensor unit
ZS Force Unoccup enable
ZS Force unocc wt delay
ZS TLO Cont Enable
ZS TLO set during occ
Zone sensor UI Mode
NETWORK SETUP CHECKLIST
User Display Configurations Menu
Metric Display
Display Language Select
LCD Contrast Adjustment
User Password Protection
View User Password Menu
Change User Password Menu
QUICK SETUP CONFIG MENU
Clock Hour and Minute
Current Date
Unit Startup Delay
Unit Control Type
Thermostat Hardware Type
Change Filter Timer
Number of Heating Stages
Ventilation Method
Free Cooling Max OAT
Fire Shutdown Switch
QUICK SETUP CHECKLIST
VALUES
UNITS
0 to 60
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
0 to 4194303
0 to 9999
0 to 60
Yes/No
enum
0 to 4194303
10 to 60
0 to 9999
0 to 9999
0 to 255
0 to 255
0 to 255
0 to 255
0 to 255
1 to 100
sec
0=degrees F
Yes/No
Yes/No
Yes/No
Yes/No
1=Dual Offsets
0=Undone,
1=Perfom,
2=Done
Yes/No
0=English,
1=Spanish,
2=French,
3=Portuguese
1 to 10
Enable/Disable
xx:xx
MM/DD/YYYY
10 to 600
sec
0=TSTAT,
1=SPACE SEN,
2=RAT SEN
0=CONV 2C2H,
1=DIGI 2C2H,
2=CONV 3C2H,
3=DIGI 3C2H
0 to 9999
hrs
0 to 2
0=NONE,
1=ECON,
2=2POS DMPR,
3=ERV,
4=ECON ERV
0 to 90
° F
0=NORM OPEN,
1=NORM CLSD,
2=NO SWITCH
0=Undone,
1=Perfom,
2=Done
141
DEFAULT
POINT
0
COVOAT
1610100
DEVRARH
30
OBJRARH
0
COVRARH
1610100
DEVRAT
1010
OBJRAT
0
COVRAT
1610100
DEVSPT
2007
OBJSPT
0
COVSPT
No
LCL_EDIT
160099
DEVST
10
POLLST
1
AISTSPT
4
AISTSPRH
255
ZSADDR1
255
ZSADDR2
255
ZSADDR3
255
ZSADDR4
255
ZSADDR5
5
ZSPOLLRT
0=degrees F
ZSUNIT
No
ZSFUNEN
No
ZSFUNWT
No
ZSTLOEN
No
ZSTLSOC
1=Dual Offsets
ZSUIM
0=Undone
CHK_NET
No
DISPUNIT
0=English
LANGUAGE
5
LCD_CONT
Enable
PASS_EBL
TIME
DATE
30
STARTDLY
0=TSTAT
CTRLTYPE
0=CONV 2C2
STATTYPE
600
FILTLIFE
2: all except below
NUMHSTGS
0: 50 Series without
FIOP heaters
1: 48 Series single
phase power,
Low Nox Gas Heat,
48FC 04---07 Low
Heat,
48FC 05---07 Med
Heat,
50GC 04---06 Low
Heat,
50GC 04---05 Med
Heat,
50GC 04 High Heat
230v 3ph and 460v,
50GC 05 High Heat
230v 3ph,
50GC 06 Med Heat
460v and 575v
0: No FIOP
VENTTYPE
1: Economizer FIOP
2: Two Position Damper
FIOP
65
MAXFREET
2: no FIOP
FIRE_CFG
0: FIOP
0=Undone
CHK_QUIK
ENTRY