Carrier 48FC Series Controls, Start-Up, Operation And Troubleshooting page 103

Single package rooftop units with systemvu controls version 1.x and puronr (r-410a) refrigerant
Hide thumbs Also See for 48FC Series:
Table of Contents

Advertisement

TABLE
DISPLAY NAME
VENTDIAG (cont)
Mins until next occupied
Fan On When Occupied
IDF Commanded RPM
Free Cooling active
Min Position in Effect
Requested Damper Pos
Econo Commanded Position
Damper Actual Position
Analog Input IAQ Control
Indoor Air Quality Level
OA Quality Level
Differential Air Quality
AQ Differential High
AQ Differential Low
AQ Diff High IAQOVERRIDE
AQ Diff Low--- IAQ OVERRIDE
IAQ override enable
IAQ Preoccupancy Purge
Preocc Purge Lockout OAT
Ok to Preoccupancy Purge
Preocc Purge Duration
In Pre--- Occupancy Purge?
Is IAQ Override Active?
IAQ Override Switch
2--- Pos Damper/ERV Channel
Supply Air Temperature
Return Air Temperature
Outdoor Air Temperature
Damper SAT deadband
T24 Min Diff in RAT--- OAT
T24 Heat/Cool End Delay
SAT heat mode sensing
Actual Heat Stage Active
Actual Cool Stage Active
OK to Use Free Cooling?
T24 Test Minimum Pos
Econo Commanded Position
T24 Test Maximum Pos
T24Econ Min Move for SAT
Damper Actual Position
VENTCURV
Econ Min at Max Fanspeed
IDF Maximum Fan Speed
Min Pos --- User Pos 1
Min Pos --- User Pos 2
Min Pos --- User Pos 3
Min Pos --- User Speed 1
Min Pos --- User Speed 2
Min Pos --- User Speed 3
User Min Pos Pnt 1 Valid
User Min Pos Pnt 2 Valid
User Min Pos Pnt 3 Valid
APPENDIX D: SystemVut Controller CCN Tables
Maintenance Tables (cont)
--- 1 to 10080
Yes/No
0 to 3000
Yes/No
0 to 100
0 to 100
0 to 100
0 to 100
0=NO IAQ,
1=DCV,
2=IAQ OVRD,
3=CTRL MINP
xxxx
xxxx
--- 5000 to 5000
0 to 5000
0 to 5000
0 to 5000
0 to 5000
Yes/No
Yes/No
0 to 70
Yes/No
5 to 120
Yes/No
Yes/No
On/Off
0=NONE,
1=MBB RLY11,
2=MBB RLY06
xxx..x
xxx.x
xxx.x
0 to 20
5 to 20
0 to 60
Enable/Disable
x
x
Yes/No
0 to 100
0 to 100
0 to 100
10 to 20
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
0 to 100
Yes/No
Yes/No
Yes/No
VALUES
UNITS
min
RPM
%
%
%
%
PPM
PPM
PPM
PPM
PPM
° F
min
° F
° F
° F
° F
° F
min
%
%
%
%
%
%
%
%
%
%
%
%
%
103
POINT NAME
WRITE STATUS
MINTILOC
FANON_OC
FSPD_RPM
FREECOOL
MIN_POS
Forcible
REQDAMP
DAMPCMD
Forcible
DAMPPOS
IAQANCFG
IAQ
Forcible
OAQ
Forcible
AQ_DIFF
DAQ_HIGH
DAQ_LOW
AQD_HIGH
AQD_LOW
IAQOVREN
IAQPURGE
IAQP_LA
OKPREOCC
IAQPTIME
PREOCCON
IAQ_OVRD
IAQ_OVRS
Forcible
EV2PCHAN
SAT
RAT
Forcible
OAT
Forcible
T24SATDB
T24RATDF
T24CHDLY
SAT_HEAT
ACTHSTGS
ACTCSTGS
OKFREECL
T24TSTMN
DAMPCMD
Forcible
T24TSTMX
T24ECSTS
DAMPPOS
MINP_MAX
SPEEDMAX
MP_UPOS1
MP_UPOS2
MP_UPOS3
MP_USPD1
MP_USPD2
MP_USPD3
MP_UPT1
MP_UPT2
MP_UPT3