IDENTIFICATION OF THE MACHINE
4.
TECHNICAL FEATURES
5.
6.
7.
8.
PROBLEMS AND SOLUTIONS
9.
10.
11.
12.
13.
14.
15.
OPERATIONAL HAZARDS
16.
WARRANTY
17.
DECLARATION OF COMPLIANCE
18.
The manual has been prepared in compliance with Directive
EC 06/42
C2168IE - WK 01/12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MiQueL EXT and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DROPSA MiQueL EXT

  • Page 1: Table Of Contents

    MiQueL EXT Air/oil modular minimal system With external pump User Operating and Maintenance Manual Original text translation Warranty Information CONTENT INTRODUCTION GENERAL DESCRIPTION IDENTIFICATION OF THE MACHINE TECHNICAL FEATURES MACHINE COMPONENTS UNPACKING AND INSTALLATION INSTRUCTIONS FOR USE PROBLEMS AND SOLUTIONS...
  • Page 2: Introduction

    1. INTRODUCTION This user and maintenance manual relates to the MiQueL EXT. Using this pump means that oils and greases can be distributed within lubrication systems even at high pressures of up to 400 bar (5880 psi). The latest version may be obtained from the Technical-Commercial Office, or by consulting our web site http://www.dropsa.com.
  • Page 3: Machine Components

    Application Machine tools Machines for cutting and bending plate Steelworks The units are supplied without accessories. The installer is responsible for providing the accessories needed for safe and correct operation (condensate separator, filters, pressure gauges, by-pass, etc…). 3. MACHINE IDENTIFICATION There is a plate on the side of the unit that displays the product code, the power supply voltages and the basic characteristics.
  • Page 4 MiQueL PRO- EXT Module Ø3 pipe removal tool Modular element outlets Mounting screws Air inlet Oil inlet Assembly system / increasing modular elements...
  • Page 5: Unpacking And Installation

    Use safety gloves or glasses as specified in the safety sheet for the lubricant. Do not use aggressive lubricants with NBR gaskets. In the case of doubt, contact the Dropsa SpA technical office to receive a detailed card about the recommended oils.
  • Page 6 6.4 ELECTRIC CONNECTIONS Connect the unit to the pump or to the pressurized reservoir using suitable piping for the working pressure that must not be greater than 2.5 times the air pressure (es.: air 6bar [87psi] – oil 15bar [217,5psi] max.). 6.5 AIR/OIL HYDRAULIC CONNECTIONS TO THE LUBRICATION NOZZLE ...
  • Page 7: Instructions For Use

    At the first start-up, it may be necessary to fill the oil pipes, wait until the lubricant exits; Check that the lubrication is suitable (if there are doubts about correct operation, the Dropsa SpA technical office can be contacted to request the inspection procedure).
  • Page 8: Disposal

    Oil MK 100 25 lt. 1525460 MiQueL BASE - Modular element 3226666 Oil MK High Performance 29 lt. 3133561 Pressurized Reservoir for MiQueL EXT – 1lt 3225465 Oil MK Stainless 20 lt 3133560 Pressurized Reservoir for MiQueL EXT – 3lt...
  • Page 9: Dimensions

    12. DIMENSIONS MiQueL - EXT Reservoir for MiQueL EXT (optional) Dimensions in mm [inch].
  • Page 10: Handling And Transport

    13. HANDLING AND TRANSPORT Before shipping, the units are carefully packed inside cardboard boxes. When transporting and storing the equipment, pay attention to the direction indicated on the boxes themselves. Upon receipt, check that the package has not been damaged and store the equipment in a dry location. Lift the equipment according to the direction shown on the cardboard package.
  • Page 11 Use of unsuitable lubricant: The specifications of the lubricant are indicated both on the unit as well as in this User and maintenance manual (in the case of doubt, contact the Dropsa S.p.A technical office). FLUIDS THAT ARE NOT PERMITTED...
  • Page 12 16. WARRANTY INFORMATION All products manufactured and marketed by Dropsa are warranted to be free of defects in material or workmanship for a period of at least 12 months from date of delivery. Extended warranty coverage applies as follows: Complete system installation by Dropsa: 24 Months All other components: 12 months from date of installation;...
  • Page 13 Besana,5 / Dropsa S.p.A. au Siège Social à Milan, Via Besana,5/ Dropsa S.p.A., Sitz in Milano, Via Besana 5/ La sociedad Dropsa S.p.a., con sede legal en Milán, Via Besana,5/ A Dropsa S.p.A, com sede em Milão, via Besana, nº 5 DICHIARA /CERTIFIES / CERTIFIE/ ZERTIFIZIERT, DASS/ DECLARA/ CERTIFICA: che il prodotto denominato/that the product called/ le produit appelè/ das Produkt mit dem Namen/ el producto que se...
  • Page 14: Distributors

    E-mail: sales@dropsa.it (Export) Fax: (+33) 01 39 86 26 36 E-mail: vendite@dropsa.it (National) E-mail: salesfr@dropsa.com Dropsa (UK) Ltd Dropsa do Brazil Ind. E Com. Ltda Unit 6, Egham Business Village, Rua Sobralia 175, Egham,Surrey,TW20 8RB Sao Paulo, Brazil Tel: (+44) 01784 - 431177...