5. Cabling of an SLite display
5.2

Data cabling of an SLite display

Necessary parts
Data linking cables.
One dummy data plug.
How to realize the data cabling of an SLite display ?
1. Connect the data cable coming from the digitizer with the data input socket of the first tile. The first tile must be one of the tiles
in the corner of the SLite display.
Note: The maximum cable length between the digitizer and the first tile may not exceed 5 meter.
2. Daisy chain the data-linking cables from the data output of previous tile to the data input of the next. This daisy chain linking can
be realized either in horizontal (recommended) or vertical directions starting in a corner of the SLite display.
3. Place a dummy data plug on the data output socket of the last tile in the chain.
4. Make sure that all plug holder clamps are locked firmly.
5. Specify in the setup controlling software how the data path is realized (horizontal or vertical) and which tile is the first in the chain.
When using a fiberlink system the fiberlink data connection is inserted between the digitizer and the first SLite
tile. The fiberlink receiver is also equipped with Barco's outdoor connector sockets.
When using a Ambient Environment Controller (AEC) the data connection of the AEC is inserted between two
SLite tiles. The AEC is also equipped with Barco's outdoor connector sockets.
Example of data cabling of an SLite display
The example below shows the data cabling, seen from the rear, of an SLite display of four tiles width and six tiles high. The data
path is realized in a horizontal direction and starts in the lower left corner (seen from the rear). Note that an AEC is included in the
data path. The settings in the control software refer to the display seen from the front. So, the first tile in the data path has to be
indicated as the lower right tile of the display.
A
B
RS232 IN
DIGITIZER
Image 5-3
A
Local PC with control software.
B
RS232 connection cable between PC and digitizer (maximum 15 meter).
C
Digitizer.
D
Data cable between digitizer and first tile (maximum 5 meter).
E
Data linking cable between tiles.
F
Dummy data plug.
30
F
E
AEC
OUT
IN
C
D
LED
WALL
OUT
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
R5976575 FIXED SLITE DISPLAY 08/03/2006
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN
OUT
OUT
IN
IN

Advertisement

Table of Contents
loading

This manual is also suitable for:

Slite 10 xpSlite 10Slite 14Slite 22

Table of Contents