Console Diagnostic Codes - Alamo Bush Hog HDE-2 Series Operator's Manual

Zero turn mowers
Table of Contents

Advertisement

Console Diagnostic Codes

When a fault is detected by the console it is displayed on the LCD (14) as a numeric code. Below is a chart of the
error codes and potential sources
ERROR
DESCRIPTION
CODE #
10
Continuous PTO clutch current to high - check PTO clutch coil resistance.
11
Function inhibited because continuous system current to high.
12
Check battery condition and connections, check starter solenoid wiring for shorts.
13
Check battery condition and connections, check PTO and PTO wiring for shorts.
14
Check battery condition and connections, check fuel solenoid and fuel solenoid wiring for shorts.
15
Check headlight wiring for shorts
16
Check battery condition and connections, check wiring for shorts.
17
Check battery condition and connections.
18
Check battery condition and connections, check starter and fuel solenoid and wiring for shorts.
19
Check battery connections and connections, check PTO and PTO wiring for shorts.
20
Check battery connections, check fuel solenoid and wiring for shorts.
21
Check battery connections, check headlight wiring for shorts.
22
Check battery condition and connections, wiring for shorts.
23
Check battery condition and connections, check all wiring for shorts.
24
Excessive system current.
25
Check PTO current.
26
Excessive system current.
27
Excessive system current, check headlights.
28
Excessive system current.
29
Excessive system current.
30
Console internal fault.
39
Console internal fault, some or all power functions disabled.
40
Console internal fault.