6.4.3 - Electrical Fast Transient Immunity Data

The system does not exhibit susceptibility to 0.5-kV/1-kV/2-kV electrical fast transients,
delivered in 5-kHz bursts to power lines. "A" result = No effect on EUT.
The system does not exhibit susceptibility 0.5-kV/1-kV/2-kV electrical fast transients, delivered in
5-kHz bursts to signal lines. The Karbon 700 PC was unaffected during testing.

6.4.4 - Surge Immunity Data

The system does not exhibit susceptibility to 1-kV line-to-line/2-kV line-to-ground, 1.2/50us-
combination wave surges delivered directly or by 90 ̊ - and 270 ̊ - phase synchronizations.
The Karbon 700 PC was unaffected during testing.

6.4.5 - Conducted Immunity Data

The system does not exhibit susceptibility to 3/1-V conducted signals applied, using the injection
probe, to the signal lines from 150 kHz to 80 MHz. Frequencies listed are samples; dwell >EUT
response time. The Karbon 700 PC was unaffected during testing.
 