6.3 - Conducted Transient Data
The table below describes the results of the transient test. The system does not exhibit
susceptibility to conducted transients delivered directly to power lines.
"A" result = No effect on EUT.
Pulse
Voltage V
1
-450
2a
+55
2b
+20
3a
-220
3b
+220
6.4 - EN 50121-3-2 Summary
The Karbon 700 PC complies with the EN 61000-6-4 radiated and conducted
emissions limits as tailored by EN 50121-3-2. The unit passes EN 50121-3-2, Table 5 levels for ESD
and radiated immunity. The unit also passes EN 50121-3-2, Tables 3 & 4 levels for EFT, conducted,
and surge immunity.
All EN 50121-3-2 testing on the Karbon 700 PC was performed without the use of an AC-DC external
power adapter. Instead, a direct DC power input was used.
6.4.1 - ESD Immunity Data
The unit does not exhibit susceptibility to 4-kV and 6-kV contact/8-kV air discharges applied
singly or repetitively, and directly or indirectly. The relative humidity during unit testing was
measured to be between 30% and 60%. The Karbon 700 PC was unaffected during testing.
6.4.2 - Radiated Immunity Data
The system does not exhibit susceptibility to 20/10/5/3-V/m radiated electric fields, amplitude
modulated at 1000 Hz, 80%, from 80 MHz to 6 GHz. Frequencies listed are samples and spots. The
Karbon 700 PC was unaffected during testing.
Application
Duration
Port
Power Entry
500
Power Entry
500
Power Entry
10
Power Entry
1 hour
Power Entry
1 hour
Cycle/PRT
Spec.
500 ms
A
200 ms
A
500 ms
A
100 ms
A
100 ms
A
Result
A
A
A
A
A