2.2.1 - DIO Connection Diagram

 
The Isolated Power Supply (ISO PSU) can be a voltage source from 5V-48V to interface with external
digital IO. The max power draw from the supply should not exceed 0.6A under normal operating
conditions. Individual DOut pins will be damaged by a load in excess of 150mA. The ISO PSU can only
be a DC Limited Power Source (LPS) power supply.

2.3 - Remote Power Switch

 
Mating power switch cables should be a twisted-pair wire with floating shield to assure proper
immunity to EMI/RFI. It is recommended to keep wires at less than 3 meters in length. Switches
should be momentary contact type only.
 
 
Pin 
Definition 
GND 
Power 
 