Figure 29: Bios Advanced Menu - Serial Port Console Redirection - Com1 Console Redirection Settings - Quanmax RAK-120S User Manual

Table of Contents

Advertisement

Figure 29: BIOS Advanced Menu - Serial Port Console Redirection - COM1 Console Redirection Settings*

Main
COM1
Console Redirection Settings
Terminal Type
Bits per second
Data Bits
Parity
Stop Bits
Flow Control
VT-UTF8 Combo Key Support
Recorder Mode
Resolution 100x31
Putty KeyPad
* This submenu appears only when enabling console redirection of COM1 in the previous higher menu.
Feature
Terminal Type
Bits per second
Data Bits
Parity
Stop Bits
Flow Control
VT-UTF8 Combo Key
Support
Recorder Mode
BIOS SETUP UTILITY
Advanced
Power
[ANSI]
[115200]
[8]
[None]
[1]
[None]
[Enabled]
[Disabled]
[Disabled]
[VT100]
Version 2.19.1266. Copyright (C) 2019, American Megatrends, Inc.
Option
[VT100], [VT100+],
[VT-UTF8], [ANSI]
[9600], [19200],
[38400], [57600],
[115200]
[7], [8]
[None], [Even], [Odd],
[Mark], [Space]
[1], [2]
[None], [Hardware
RTS/CTS]
[Disabled], [Enabled]
[Disabled], [Enabled]
Boot
Description
Emulation:
ANSI: Extended ASCII char set.
VT100: ASCII char set.
VT100+: Extends VT100 to support color, function keys, etc.
VT-UTF8: Uses UTFb encoding to map Unicode
Select serial port transmission speed. The speed must be
matched on the other side. Long or noisy lines may require
lower speeds.
Select data bits.
A parity bit can be sent with the data bits to detect some
transmission errors.
Even: parity bit is 0 if the number of 1's in the data bits is even.
Odd: Parity bit is 0 if the number of 1's in the data bits is odd.
Mark: Parity bit is always 1.
Space: Parity bit is always 0.
Stop bits indicate the end of a serial data packet. (A start bit
indicates the beginning). The standard setting is 1 stop bit.
Communication with slow devices may require more than 1 stop
bit.
Flow control can prevent data loss from buffer overflow. When
sending data, if the receiving buffers are full, a 'stop' signal can
be sent to stop the data flow. Once the buffers are empty, a
'start' signal can be sent to re-start the flow.
Select whether to enable or disable VT-UTF8 Combination Key
Support for ANSI/VT100 terminals.
With this mode enabled only text will be sent. This is to capture
RAK-120S - User Guide, Rev. 1.0
Security
Save & Exit
→ ←: Select Screen
↑ ↓: Select Item
Enter: Select
+/-: Change Opt.
F1: General Help
F2: Previous Values
F3: Optimized Defaults
F4: Save & Exit
ESC: Exit
// 62