7/ Installation Instructions

The RAK-120S system is designed for operating:
in a rack or cabinet by use a rackmount kit
Expansion card installation should be performed before installing the RAK-120S into
the rack / cabinet.
Whenever possible, unpack or pack this product only at EOS/ESD safe work stations.
Where a safe work station is not guaranteed, it is important for the user to be
electrically discharged before touching the product with his/her hands or tools. This is
most easily done by touching a metal part of the system chassis.
Do not handle this product out of its protective enclosure while it is not used for
operational purposes unless it is otherwise protected.
Prior any installation work, ensure that there are no live wires on the installation site.
Do not handle the device if there is any damage visible.
Do not operate the RAK-120S with foreign objects inside the chassis.
Further do not insert any retrieval device into the device while it is connected to power.
We reject all liability for any and all damages resulting from operation of the unit with
foreign objects inside the chassis.
The RAK-120S has to be installed and operated only by trained and qualified personnel.
Only personnel with appropriate qualifications, trainings and authorization are
permitted to install and work with the RAK-120S.
This device shall only be installed in or connected to systems that fulfill all necessary
technical and specific environmental requirements.
The unit must be placed such that there is sufficient space in front and rear of it for
connecting the cables to the I/O interface connectors and for operating the power
button.
Leave sufficient free space around the unit to prevent the device from possibly
overheating!
Refer also to section 10.1.2 "Mechanical Specifications".
The RAK-120S must be firmly attached to a clean flat and solid mounting surface. Use
proper fastening materials suitable for the mounting surface. Ensure that the mounting
surface type and the used mounting solution safely support the load of the RAK-120S
and the attached components.
Please follow the local/national regulations for grounding.
The voltage feeds must not be overloaded. Adjust the cabling and the overcurrent
protection to correspond with the electrical figures indicated on the type label.
The type label is located next to the access cover of the system.
It is recommended that the last cable attached to the system should be the power
cable! Refer to the section 7.2 "DC Power Connection" and chapter 8/ "Starting Up".