Maytag MDE20PDAGW Installation Instructions Manual page 26

Commercial gas or electric dryer
Hide thumbs Also See for MDE20PDAGW:
Table of Contents

Advertisement

Available languages

Available languages

ELECTRONIC CONTROL SETUP INSTRUCTIONS
(PD & PN MODELS ONLY)
Code
Explanation
PAYMENT MODE (COIN/DEBIT OPTION)
J. Cd
J. Cd
Both coin and debit selected. Press the DELICATES
button 3 consecutive times to change this selection.
J. C_
Coins selected, debit disabled. Press the DELICATES
button 3 consecutive times to change this selection.
J._d
Debit Card selected, coins disabled. Press the
DELICATES button 3 consecutive times to change
this selection.
J. Ed
Enhanced Debit is self-selected when a Generation
2 card reader is installed in the dryer. The Ed option
cannot be manually selected or deselected.
• Press the NORMAL button once to advance to
next code.
PRICE SUPPRESSION OPTION
L. 00
This option is either NOT SELECTED "OFF" or
SELECTED "ON." This option causes the customer
display to show "ADD" or "AVAILABLE" rather than
the amount of money to add. (Used mainly in debit
installations.)
L. 00
Not Selected "OFF."
L. PS
Selected "ON."
• Press the DELICATES button once to change this
selection.
• Press the NORMAL button once to advance to
next code.
CLEAR ESCROW OPTION
n. CE
This option is either NOT SELECTED "OFF" or
SELECTED "ON." When selected, money held in
escrow for 30 minutes without further escrow or
cycle activity will be cleared.
n. 00
Not Selected "OFF."
n. CE
Selected "ON."
• Press the DELICATES button once to change this
selection.
• Press the NORMAL button once to advance to
next code.
26
END of SET-UP PROCEDURES
EXIT FROM SET-UP MODE
Single-Load Models: Reinstall access door.
DIAGNOSTIC GUIDE
If the set-up mode is entered and one of the following has
occurred, the appropriate diagnostic code will be in the display.
SINGLE DRYERS
CODE
d1
d4
d5
d9
d12
d13
d16
EXPLANATION
Dryer door sense error on
control board or due to power
line interference (cycles and
price display disabled until
diagnostic code is manually
cleared).
Dryer motor control circuit
error (cycles and customer
display disabled until
diagnostic code is manually
cleared).
Blocked coin 1 or coin drop
control circuit failure (coin
recognition and customer
display disabled while
blockage persists).
Voltage detected below
90 VAC for 8 seconds.
Motor sense error on control
board or due to power line
interference (cycles and
customer display disabled until
diagnostic code is manually
cleared).
Blocked coin 2 or coin drop
control circuit failure (coin
recognition and price display
disabled while blockage
persists).
Not receiving communications
from installed debit card reader
in Enhanced (Generation 2)
Debit mode.

Advertisement

Table of Contents
loading

Table of Contents