Component Input Power - Avaya Virtual Services Platform 9000 Series Installation Manual

Hide thumbs Also See for Virtual Services Platform 9000 Series:
Table of Contents

Advertisement

Technical specifications
Parameter
Input volt-ampere (VA)
Efficiency
Input power consumption
Heat dissipation (thermal
output)
Hold-up time (See note 1.)
Note 1: Measurementstarts at zero crossing of the AC voltage. Measurement made at
fullload and voltage is allowed to decay to 44 VDC.
The following table lists the DC output power specifications.
Table 6: DC output power specifications
Maximum main output power
Maximum main output current
Auxiliary output voltage / power
Output voltage set-point
Mean time between failures (See
note 1.)
Note 1:Per telcordia SR-332, 25 C, full load, method 1, case III

Component input power

The following table provides input power specifications for the Virtual Services Platform 9000
components.
Important:
The system reserves the following power requirements:
• 80 Watts (W) each for the primary and secondary Control Processor (CP) modules
• 70 W each for the Switch Fabric (SF) modules located in slots 1 and 4
• 150 W each for the two IO fan trays
42
Installation — Chassis
Specification at input
voltage 100-120 V AC
1445 VA
85% minimum, 90% typical
1416 W
724 British Thermal Unit
(BTU)/hour
25 ms
Parameter
Comments? infodev@avaya.com
Specification at input voltage
100–120 V AC
1200 W
22 A
5 V DC / 3.75 W
54 V DC
400 000 hours
Specification at input
voltage 200-240 V AC
2325 VA
88% minimum, 93% typical
2277 W
933 BTU/hour
20 ms
Specification at
input voltage 200–
240 V AC
2000 W
37 A
5 V DC / 3.75 W
54 V DC
400 000 hours
October 2011