Summary of Contents for V-ZUG CookTopInduction V4000 CTI4T64 Series
Page 1
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob The appliance should be installed by qualified personnel only. Each step must be carried out and checked in full in the order specified. Validity These installation instructions apply to the following models: Model number With normal mounting frame With DualDesign...
Page 2
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Installation accessories supplied Oversize mounting frame: Designation Art. no. Adjusting brace set H61548 Flush installation: Designation Art. no. Cementing-in instructions J004133 Sealing strip set H63283 Spacer set H60330 Accessories For all installation variants: Designation Art.
Page 3
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Electrical connection Electrical connections must be carried out by qualified personnel in accordance with the guidelines and standards for low-voltage installations and the specifications of the local electricity supply companies. Refer to the identification plate for information on the required mains voltage, current type and fuse protection.
Page 4
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob General information about installation ▪ The worktop must be flat so that it is sufficiently sealed against the ingress of liquids. ▪ In order to guarantee good ventilation, a space of at least 10 mm in height is necessary beneath the appliance. Overlying installation with normal mounting frame The layout of the hob to be fitted may differ from the hob illustrated! CTI4T64MMSLC,...
Page 5
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Overlying installation The layout of the hob to be fitted may differ from the hob illustrated! CTI4T64MMSLD, CTI4T74MMSLD, CTI4T64MMSOLD CTI4T74MMSOLD Cable length 1.7 m Cable length 1.7 m Y – Y Drawer/cabinet * The required clearance must be observed! Type...
Page 6
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Flush installation The layout of the hob to be fitted may differ from the hob illustrated! CTI4T64MMSLD, CTI4T74MMSLD, CTI4T64MMSOLD CTI4T74MMSOLD Cable length 1.7 m Cable length 1.7 m Detail Z R0–5 Steel angle mounted with adhesive or screws...
Page 7
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Installation with oversize mounting frame The layout of the hob to be fitted may differ from the hob illustrated! CTI4T64MMSLU, CTI4T64MMSOLU Cable length 1.7 m Y – Y Drawer/cabinet * The required clearance must be observed! Type A Depends on producer...
Page 8
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Variable areas of the special cut-out dimensions CTI4T64MMSLU, CTI4T64MMSOLU Aim for ≤R10 6 adjusting braces Reinforcement of the cut-outs with Arrangement of the adjusting braces a complete chrome-nickel steel cover Plate for chrome-nickel steel cover Reinforcing slats: Warning, glass breakage:...
Page 9
1065985-R01 Installation instructions 23/04/2019 CTI4T64/74 CookTopInduction V4000 1065985-R01 Glass ceramic hob Installation of the ventilation protective plate with 3 mm ventilation gap at the front A protective plate is necessary for the adequate ventilation of the hob. The distance between the underside of the appliance and the protective plate must be ≥10 mm. Air gap over entire width of Well-fitting seal over Caution: Mains cable must...