Bristan PM SQSHXDIV C Fitting Instructions Manual
Bristan PM SQSHXDIV C Fitting Instructions Manual

Bristan PM SQSHXDIV C Fitting Instructions Manual

Prism single control surface mounted shower valve with rigid riser & diverter to handset

Advertisement

Guarantee & Registration
Guarantee
All products are manufactured to the highest standards and 5-year guarantee covers any defect in
manufacture.
Any part found to be defective during the above guarantee period will be replaced without charge
providing that the product has been installed in accordance with our instructions, used as intended and
maintained/serviced as recommended.
In the unlikely event that any problems are encountered with this product's performance on installation,
you must obtain guidance/authorisation from our Customer Service Department before any remedial
action is taken and be able to supply proof and date of purchase.
The guarantee excludes damage caused by accident, misuse or neglect and does not cover the
following:
-
Those components subject to wear and tear such as 'O' rings and washers etc,
-
Damage caused by faulty installation,
-
Damage caused by any waterborne debris,
-
Damage caused by improper cleaning products,
-
Damage caused by the use of non-Bristan parts,
-
The product being used for a purpose other than intended.
The company reserves the right, in the event of a claim not covered by the guarantee, to charge the
claimant for parts and labour at current rates. This guarantee is given in addition to and does not affect your
statutory rights.
In the interests of continuous product development we reserve the right to alter the specification as
necessary.
Registration
To register your product with us please complete and return the enclosed registration card.
PRODUCT CODE: PM SQSHXDIV C
TELEPHONE HELP LINE: 0844 701 6273
(FI PM SQSHXDIV)
11
(REV.D4)
Prism Single Control Surface
Mounted Shower Valve with
Rigid Riser & Diverter to
Handset
Fitting
Instructions
(AJ)
Please keep these instructions for future reference
Before starting any installation project please consider:
Prior to drilling into walls, check there are no hidden electrical
wires, cables or water supply pipes with the aid of an
electronic detector. If you use power tools do not forget:
- Wear eye protection
- Unplug equipment after use
800356/D

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PM SQSHXDIV C and is the answer not in the manual?

Questions and answers

Summary of Contents for Bristan PM SQSHXDIV C

  • Page 1 Damage caused by faulty installation, Damage caused by any waterborne debris, Damage caused by improper cleaning products, Damage caused by the use of non-Bristan parts, The product being used for a purpose other than intended. Prism Single Control Surface The company reserves the right, in the event of a claim not covered by the guarantee, to charge the claimant for parts and labour at current rates.
  • Page 2 Specifications Fault Finder General Fault Cause Rectification The installation, commissioning and maintenance must be carried out in accordance with Clear debris from shower head. - Shower head blocked. No or reduced flow and/or fluctuating instructions supplied and be installed by qualified and competent persons. Open valve.
  • Page 3: Compatible Systems

    Cleaning Compatible Systems These finishes should be cleaned using a mild washing up detergent or soap solution, rinsed Instantaneous heated system (Gas or Electric) with clean water and wiped dry with a soft cloth. Shower inc. non-return valves Service Guide Isolating valve If your thermostatic mixing valve fails to operate it could be the result of incorrect installation.
  • Page 4: Maximum Temperature Setting

    Compatible Systems Maximum Temperature Setting For optimum performance from the thermostatic mixing valve, see the table below for The maximum mixed water temperature should be limited to ensure no undesirable recommendations for flow limiter selection. temperature is obtained. If necessary adjust as follows - 1) Turn the knob anti-clockwise to the maximum temperature position.
  • Page 5: Installation

    Installation Installation The installation, commissioning and maintenance must be carried out in accordance with Using complete valve and kit (see fig.1 on previous page) instructions supplied and be installed by qualified and competent persons. Installations must comply with all Local and National Water Authority Regulations, and Building and 1) With the shower mixing valve installed, connect the rigid riser (with brackets and slider) onto Plumbing Regulations.
  • Page 6 Fig. 1 Valve Assembly WASHER Exploded diagram showing valve components and their spare kits codes. SHOWER ROSE PART DECRIPTION NUMBER NUMBER COMPLETE CARTRIDGE ASSEMBLY SKAK4000 BACKPLATE EXP - 220019 COMPLETE ELBOW ASSEMBLY SKINLET-7 WALL BRACKET WALL COVER PLATE 220039 HANDSET WASHER DRAWING SHOWN WITHOUT HANDSET HOLDER...