Eaton Power Defense NRX NF Series Instruction Leaflet
Eaton Power Defense NRX NF Series Instruction Leaflet

Eaton Power Defense NRX NF Series Instruction Leaflet

Castell key lock accessory

Advertisement

Quick Links

Instruction Leaflet
Castell key lock accessory
Instructions apply to:
UL489
IEC
UL1066/ANSI
(1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK
ON THE EQUIPMENT.
(2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT
BREAKER CANNOT BE REMOVED TO A SAFE WORK LOCATION.
(3) DRAWOUT CIRCUIT BREAKERS SHOULD BE LEVERED (RACKED) OUT TO THE
DISCONNECT POSITION.
(4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED TO THE OFF POSITION AND
MECHANISM SPRINGS DISCHARGED.
FAILURE TO FOLLOW THESE STEPS FOR ALL PROCEDURES DESCRIBED IN THIS
INSTRUCTION LEAFLET COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY
DAMAGE.
THE INSTRUCTIONS CONTAINED IN THIS IL AND ON PRODUCT LABELS HAVE TO
BE FOLLOWED. OBSERVE THE FIVE SAFETY RULES:
– DISCONNECTING
– ENSURE THAT DEVICES CANNOT BE ACCIDENTALLY RESTARTED
– VERIFY ISOLATION FROM THE SUPPLY
– EARTHING AND SHORT-CIRCUITING
– COVERING OR PROVIDING BARRIERS TO
ADJACENT LIVE PARTS
DISCONNECT THE EQUIPMENT FROM THE SUPPLY. USE ONLY AUTHORIZED
SPARE PARTS IN THE REPAIR OF THE EQUIPMENT. THE SPECIFIED MAINTENANCE
INTERVALS AS WELL AS THE INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST
BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO
THE SWITCHBOARD.
Power
Defense™
IL01301050E
: PD-NF, Series NRX NF
: PD-NF, IZMX16
: Series NRX NF
WARNING
WARNING
Supersedes June 2016
Effective January 2019
UL489
: PD-RF
IEC
: PD-RF, IZMX40
Power Defense – ICCB
Series NRX
IZMX

Advertisement

loading
Need help?

Need help?

Do you have a question about the Power Defense NRX NF Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton Power Defense NRX NF Series

  • Page 1 Power Defense – ICCB Supersedes June 2016 Series NRX Instruction Leaflet IL01301050E Effective January 2019 IZMX Castell key lock accessory Instructions apply to: UL489 : PD-NF, Series NRX NF UL489 : PD-RF : PD-NF, IZMX16 : PD-RF, IZMX40 UL1066/ANSI : Series NRX NF WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT.
  • Page 2: Section 1: General Information

    (E) M3 x 5 mm mounting screw (2) (F) Fiber retaining washer (2) (G) Cylinder mounting screw (2) (not supplied) (H) Lever assembly mounting nut (1) (I) Lever assembly mounting screw(1) (J) Lever assembly (1) (K) Button support (1) EATON www.eaton.com...
  • Page 3: Section 2: Installation Of Key Interlock

    (I) into the nut (H). Soep 6: Install the button support (K) by sliding it over the mounting plate (D). Ensure the grooves are seated against the mounting plate on top and bottom. Figure 3. Soep 2. NF frame. EATON www.eaton.com...
  • Page 4 Soep 7. NF frame. close. 3. Insert the key and rotate 90° clockwise. Press the green button to Mounting close. The breaker should close. Mounting holes screws (E) Side plate Pushbutton Sheet metal face plate Figure 6a. Soep 7. RF frame. EATON www.eaton.com...
  • Page 5 SecoiNn 3: RemNval Nf key inoerlNck To remove the key interlock, perform Steps 1 and 2 of Section 2. Complete the removal process by reversing the process as described in Steps 4 through 7 of Section 2. Replace the front cover. EATON www.eaton.com...
  • Page 6: Disclaimer Of Warranties And Limitation Of Liability

    THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability, or otherwise for any special, indirect, incidental, or consequential damage or loss...