Instruction Leaflet
Installation and Removal Instructions
for Series NRX Front Connect Adapters
Instructions apply to:
Series NRX, Type RF Frame
IEC, IZMX40
4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010)
(1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK
ON THE EQUIPMENT.
(2) ALWAYS DE-ENERGIZE PRIMARY AND SECONDARY CIRCUITS IF A CIRCUIT
BREAKER CANNOT BE REMOVED TO A SAFE WORK LOCATION.
(3) DRAWOUT CIRCUIT BREAKERS SHOULD BE LEVERED (RACKED) OUT TO THE
DISCONNECT POSITION.
(4) ALL CIRCUIT BREAKERS SHOULD BE SWITCHED TO THE OFF POSITION AND
MECHANISM SPRINGS DISCHARGED.
FAILURE TO FOLLOW THESE STEPS FOR ALL PROCEDURES DESCRIBED IN THIS
INSTRUCTION LEAFLET COULD RESULT IN DEATH, BODILY INJURY, OR PROPERTY
DAMAGE.
THE INSTRUCTIONS CONTAINED IN THIS IL AND ON PRODUCT LABELS HAVE TO
BE FOLLOWED. OBSERVE THE FIVE SAFETY RULES:
– DISCONNECTING
– ENSURE THAT DEVICES CANNOT BE ACCIDENTALLY RESTARTED
– VERIFY ISOLATION FROM THE SUPPLY
– EARTHING AND SHORT-CIRCUITING
– COVERING OR PROVIDING BARRIERS TO ADJACENT LIVE PARTS
DISCONNECT THE EQUIPMENT FROM THE SUPPLY. USE ONLY AUTHORIZED
SPARE PARTS IN THE REPAIR OF THE EQUIPMENT. THE SPECIFIED MAINTENANCE
INTERVALS AS WELL AS THE INSTRUCTIONS FOR REPAIR AND EXCHANGE MUST
BE STRICTLY ADHERED TO PREVENT INJURY TO PERSONNEL AND DAMAGE TO
THE SWITCHBOARD.
IL01301056E
• WARNING
• WARNING
effective August 2011
Series NRX

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NRX Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Eaton NRX Series

  • Page 1 Instruction Leaflet IL01301056E effective August 2011 Series NRX Installation and Removal Instructions for Series NRX Front Connect Adapters Instructions apply to: Series NRX, Type RF Frame IEC, IZMX40 4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) • WARNING (1) ONLY QUALIFIED ELECTRICAL PERSONNEL SHOULD BE PERMITTED TO WORK ON THE EQUIPMENT.
  • Page 2: Section 1: General Information

    • IMPORTANT Figure 3. Step 2. IT IS RECOMMENDED THAT THE REAR OF THE FRONT CONNECT TERMINALS BE INSULATED FROM ANY GROUNDED METAL TO HELP PREVENT Removal: Reverse the procedure just described to remove the ACCIDENTAL CONTACT. adapters. EATON CORPORATION www.eaton.com...
  • Page 3 Installation and Removal Instructions Instruction Leaflet IL01301056E for Series NRX Front Connect Adapters effective August 2011 Optional Barrier Optional Barrier Figure 4. Drawout 800-3200A Vertical Bus (dimensions in inches [mm]) Figure 4a. Fixed Vertical Bus (dimensions in inches [mm]) EATON CORPORATION www.eaton.com...
  • Page 4: Disclaimer Of Warranties And Limitation Of Liability

    Disclaimer of warranties and limitation of liability The information, recommendations, descriptions, and safety notations In no event will Eaton be responsible to the purchaser or user in in this document are based on Eaton Corporation’s (“Eaton”) contract, in tort (including negligence), strict liability, or otherwise experience and judgment, and may not cover all contingencies.
  • Page 5 Instruction Leaflet IL01301056E gültig ab August 2011 Series NRX Montageanweisung für Series NRX Frontseitige Hauptanschlüsse Die Montageanweisung ist für folgende Baugrößen gültig: Series NRX, Type RF Frame IEC, IZMX40 4000 NRX RF DRAWOUT SUBTITLE IMAGE (12/15/2010) • WARNUNG (1) DIE INSTANDHALTUNG DARF NUR DURCH ENTSPRECHEND ELEKTRONTECHNISCH QUALIFIZIERTES PERSONAL ERFOLGEN.
  • Page 6: Abschnitt 1: Allgemeine Informationen

    Drehmomentschlüssel. Siehe Abbildungen 4 für die jeweils möglichen Konfigurationen. Schritt 2: Befestigen Sie die übrigen fünf Sammelschienenanschlüsse (sieben für 4-polige Schalter) wie in Schritt 1 beschrieben (siehe Abbildung 3). Abbildung 3. Shritt 2 Demontage: Um die Anschlüsse zu entfernen, schrauben Sie sie wieder ab. EATON CORPORATION www.eaton.com...
  • Page 7 Montageanweisung für Series NRX Instruction Leaflet IL01301056E Frontseitige Hauptanschlüsse gültig ab August 2011 Phasenrennplatten Phasenrenn- platten Abbildung 4. 800-3200A Vertikale Sammelschienenanschlüsse (Bemaßung in Zoll [mm]) Abbildung 4a. Frontanschlüsse für Festeinbauschalter (Bemaßung in Zoll [mm]) EATON CORPORATION www.eaton.com...
  • Page 8 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com Power Chain Management is a registered © 2011 Eaton Corporation Trademark of Eaton Corporation All Rights Reserved Printed in USA All other Trademarks are property of their Publication No. IL01301056EH01 respective owners.

Table of Contents