Turbo Instrument Controller (TIC) Serial Communications
Description
TIC Instrument Controller
TIC Instrument Controller 6-Gauge
TIC Instrument Controller 6-Gauge Capacitance Manometer
TIC Turbo Controller 100 W
TIC Turbo Controller 200 W
TIC Turbo & Instrument Controller 100 W
TIC Turbo & Instrument Controller 200 W
Instruction Manual
Note:
Laptop PC not included
D397-30-880
Issue H Original
Item Number
D397-00-000
D397-01-000
D397-02-000
D397-11-000
D397-12-000
D397-21-000
D397-22-000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the D397-00-000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Edwards D397-00-000

  • Page 1 Instruction Manual Turbo Instrument Controller (TIC) Serial Communications Note: Laptop PC not included Description Item Number TIC Instrument Controller D397-00-000 TIC Instrument Controller 6-Gauge D397-01-000 TIC Instrument Controller 6-Gauge Capacitance Manometer D397-02-000 TIC Turbo Controller 100 W D397-11-000 TIC Turbo Controller 200 W D397-12-000 TIC Turbo &...
  • Page 2 This page intentionally blank.
  • Page 3: Table Of Contents

    For return of equipment, complete the HS Forms at the end of this manual. Table Page Objects accessed via the PC serial comms ................4 Abbreviations ......................11 Serial comms response codes ..................12 © Edwards Limited 2012. All rights reserved. Page i Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 4 D397-30-880 Issue H This page has been intentionally left blank. Page ii © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 5: Introduction

    D397-30-880 Issue H Introduction Scope This manual provides Operation instructions for serial interface communications to the Edwards Turbo Instrument Controller product range, part numbers: Description Item Number TIC Instrument Controller D397-00-000 TIC Instrument Controller 6-Gauge D397-01-000 TIC Instrument Controller 6-Gauge Capacitance Manometer...
  • Page 6: Responses

    If there is more than one item in the data field, each item is separated by a semi colon(;). Page 2 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 7: Tic Serial Protocol Messages

    1.3. Wait for the reply before sending in another message even if the new message is for the TIC or 'other' pump. © Edwards Limited 2012. All rights reserved. Page 3 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 8: Objects Accessed Via The Pc Serial Comms

    Read start fail time; droop fail time 0 - 30 mins Write start fail time; droop fail time Config type not needed Page 4 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 9 Read user gauge name - 4 characters 0-9, A-Z Set user gauge name Config type = 68 Commands – see Accept new gauge command list On/off Zero/calibrate/degas © Edwards Limited 2012. All rights reserved. Page 5 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 10 Turbo slaved = 1 Read permanently on or turbo slaved Permanent = 0 Write permanently on or turbo slaved Config type not needed Page 6 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 11 Gauge IDs can be in any order and can be repeated. 0 (zero) ID entry means don’t show this position but there must be a minimum of three non-zero entries. © Edwards Limited 2012. All rights reserved. Page 7 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 12 System off will turn off objects marked with a 1 in the setup off field State 0 - 4 System status - state; alert ID; priority Page 8 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 13 Write CapMan setup - range;units 2 = 0.2 Config type = 73 3 = 1 ..10 = 2000 2 = mBar 3 = Torr © Edwards Limited 2012. All rights reserved. Page 9 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 14 The pump shall accept the wildcard object ID 0 for a ?S and return information from the TIC Status object 902. The following are examples of abbreviations and codings, with their meanings, which appear in subsequent paragraphs. Page 10 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 15: Abbreviations

    ID and p is the priority. Number of characters per parameter is as required to represent the value. where d is 0 = pump off, 1 = pump on. © Edwards Limited 2012. All rights reserved. Page 11 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 16: Additional Information

    Operation took too long Invalid config ID 1.7.2 Priority warning alarm = 2/3 1.7.3 Alert ID No Alert ADC Fault ADC Not Ready Page 12 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 17 No Tube = 42 Use Gauges 4-6 = 43 Degas Inhibited = 44 IGC Inhibited = 45 Brownout/Short = 46 Service due © Edwards Limited 2012. All rights reserved. Page 13 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 18: Snvt Values

    Gauge Connected New Gauge Id Gauge Change Gauge In Alert Striking Initialising Calibrating Zeroing Degassing = 10 = 11 Inhibited = 12 Page 14 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 19: Full Pump States

    = 18 AIMX = 19 AIGC_I2R = 20 AIGC_2FIL = 21 ION_EB = 22 AIGXS = 23 USER = 24 = 25 © Edwards Limited 2012. All rights reserved. Page 15 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 20: Pump Types

    = 10 //TIC only supports this in parallel form nEXT - 232 = 11 nXDS = 12 Not yet identified = 99 Page 16 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 21: Index

    Query setup ..........3 Query value ..........3 Responses ...........2 Scope ............1 Serial comms response codes (*Cnnn x, *S, *V) ..12 Setup ............2 © Edwards Limited 2012. All rights reserved. Page 17 Edwards and the Edwards logo are trademarks of Edwards Limited.
  • Page 22 D397-30-880 Issue H This page has been intentionally left blank. Page 18 © Edwards Limited 2012. All rights reserved. Edwards and the Edwards logo are trademarks of Edwards Limited.