6.0
Fault causes
Overview of faults/LED displays
Fault
No active LED
Green LED
continuously flashing
Yellow LED
continuously flashing
Red LED
continuously flashing
– Permanent faults
The bearing monitoring unit detects conventional interfering frequencies in the high frequency range (> 2.5 kHz).
The operation of the fan on the frequency inverter can result in faults or the faulty activation of the monitoring
unit and it is therefore not permitted!
6.1

Other faults

Fault
No data displayed
(no communication)
6.2

Maintenance and servicing

Maintenance should be carried out on the bearing monitoring unit when maintenance is carried out on the unit to be
monitored (fan, motor, etc.). In this respect, the maintenance intervals in the relevant fan operating instructions must be
observed!
The maintenance of the Bearing Condition Diagnostic System (LZD) shall not replace the maintenance plan for
the fan used.
(Possible) Causes
No power supply
Defective fuse
Start sequence
Temperature outside of the defined
range (Default - 30 °C ... +50 °C)
Fault internal PT100
Sensor error
Fault Diagnostic module
(Possible) Causes
Wiring error
False or erroneous addressing
9
Measures
Check operating voltage (230V, 50 Hz)
Contact service team
Wait for start sequence (Default 2 minutes)
Check default settings
Check sensor connection
Check default settings
Contact service team
Check sensor connection
Check default settings (activate bearing
and temperature monitoring separately)
Contact service team
Measures
Check cabling
Check correct addressing,
Address switch (hex) = Slave address (dec)
Double address allocation in network
Missing restart of unit after
address change
UK