Zone Programming
For keypad zone programming, see page 16.
Zone Definitions
01 = Entry Delay 1
02 = Entry Delay 2
03 = Entry Delay 1 (Full Arm)
04 = Entry Delay2 (Full Arm)
05 = Follow
06 = Follow (Sleep/Full Arm)
07 = Follow (Full Arm)
08 = Instant
09 = Instant (Sleep/Full Arm)
10 = Instant (Full Arm)
* Flex-Instant = Zone will follow the delay at section [720], (default is 15 seconds / 0 = instant zone)
** On-board hardwire control panel zones only
† APR-ZX8 inputs do not support fire zones.
For 2-wire smoke installations (not supported by SP5500), these definitions apply to Zone 1 Input
only. Section [705], option [3] must be enabled.
For 4-wire smoke installations, use any panel on-board zone input.
Partition Assignment
[1]- Partition 1
[2]- Partition 2
[3]- Both partitions
10
Stay Arm
Sleep Arm
Entry Delay 1
Entry Delay 1
Entry Delay 2
Entry Delay 2
Not Armed
Not Armed
Not Armed
Not Armed
Follow*
Follow*
Not Armed
Follow*
Not Armed
Not Armed
Instant*
Instant*
Not Armed
Instant*
Not Armed
Not Armed
Zone Options
[1] = Auto-zone Shutdown
[2] = Bypassable Zone
[3] = RF Supervision
[4]
[5]
OFF OFF Audible Alarm
OFF ON
Pulsed Alarm
ON
OFF Silent Alarm
ON
ON
Report Only
[6] = Intellizone
[7] = Delay alarm transmission
[8] = Force Zone
Fully Arm
Zone Definitions
Entry Delay 1
11 = Instant Fire†
Entry Delay 2
12 = Delayed Fire†
Entry Delay 1
13 = Instant Fire Silent†
Entry Delay 2
14 = Delayed Fire Silent†
Follow*
15 = 24Hr. Buzzer
Follow
16 = 24Hr. Burglary
Follow
17 = 24Hr. Hold-up
Instant*
18 = 24Hr. Gas
Instant
19 = 24Hr. Heat
Instant
20 = 24Hr. Water
21 = 24Hr. Freeze
22 = 24hr. Panic
23 = Instant No Pre-Alarm
24 = Follow No Pre-Alarm
25 = Keyswitch Maintain**
26 = Keyswitch Momentary**
Keyswitch Options (25-26)
[1]- N/A
[2]- N/A
[3]- N/A
[4] OFF = Disarm
ON = Disarm only if Stay/
Sleep armed
[5] = Arm only
[6] = Stay arming*
[7] = Sleep arming*
[8] = N/A
* Select only one. If all are off,
keyswitch will regular arm.
Programming Guide
Need help?