Appendix 2: Automatic Report Code List

System Event
Arming with User Code (##)
Auto arming
Late to close
No movement
Partial arming
Quick arming
Arm with PC software
Disarm with User Code (##)
Disarm after alarm* with User Code (##)
Cancel alarm** with User Code (##)
Auto-arming cancellation
Disarm with PC software
Disarm after an alarm with PC software
Cancel alarm with PC software
Cancel paramedic alarm
Zone bypassed (##)
Zone alarm (##)
Fire alarm (##)
Zone alarm restore (##)
Fire alarm restore (##)
Panic 1 - emergency
Panic 2 - medical
Panic 3 - fire
Recent closing
Global zone shutdown
Duress alarm
Keypad lockout
Zone shutdown (##)
Zone tampered (##)
Zone tamper restore (##)
AC failure
Battery failure
Auxiliary supply trouble
Bell output current limit
Bell absent
Clock lost
Fire loop trouble
Communication fail
RF interference
TLM trouble restore
AC failure restore
Battery failure restore
* An armed system is or was in alarm and was disarmed by a user.
** A disarmed system is or was in alarm (e.g. 24Hr. zone) and was disarmed by a user.
Magellan / Spectra SP
Default Contact ID Report Code
3 4A1 - Close by user
3 4A3 - Automatic close
3 452 - Late to close
3 452 - Late to close
1 456 - Group bypass
3 4A8 - Quick arm
3 4A7 - Remote arm/disarm
1 4A1 - Open by user
1 4A1 - Open by user
1 4A6 - Cancel by user
1 464 - Deferred open/close
1 4A7 - Remote arm/disarm
1 4A7 - Remote arm/disarm
1 4A6 - Cancel by user
1 4A6 - Cancel by user
1 57A - Zone bypass
1 13A - Burglary alarm
1 11A - Fire alarm
3 13A - Burglary alarm restore
3 11A - Fire alarm restore
1 12A - Panic alarm
1 1AA - Medical alarm
1 115 - Pull station
3 459 - Open/Close
1 575 - Group bypass
1 121 - Duress
1 421 - Access denied
1 57A - Zone bypass
1 144 - Sensor tamper
3 144 - Sensor tamper restore
1 3A1 - AC loss
1 3A9 - Battery test failure
1 3AA - System trouble
1 321 - Bell 1
1 321 - Bell 1
1 626 - Time/date inaccurate
1 373 - Fire trouble
1 354 - Communication fail
1 344 - RF receiver jam detection
3 351 - Telco 1 fault restore
3 3A1 - AC loss restore
3 3A9 - Battery test restore
Default SIA Report Code
CL - Closing report
CA - Automatic closing
OT - Late to close
NA - No activity
CG - Close area
CL - Closing report
CQ - Remote arming
OP - Opening report
OP - Opening report
OR - Disarm from alarm
CE - Closing extend
OQ - Remote disarming
OR - Disarm from alarm
OR - Disarm from alarm
MH - Medical alarm restore
UB - Untyped zone bypass
BA - Burglary alarm
FA - Fire alarm
BH - Burglary alarm restore
FH - Fire alarm restore
PA - Panic alarm
MA - Medical alarm
FA - Fire alarm
CR - Recent closing
CG - Close area
HA - Hold-up alarm
JA - User code tamper
UB - Untyped zone bypass
TA - Tamper alarm
TR - Tamper restoral
AT - AC trouble
YT - System battery trouble
YP - Power supply trouble
YA - Bell fault
YA - Bell fault
JT - Time changed
FT - Fire trouble
YC -Fail to communicate
XQ - RF Interference
LR - Phone line restoral
AR - AC restoral
YR - System battery restoral