Advertisement

SP-RANGE
SP25 PEELER
SP12 & SP25 – SERIES 4
INSTALLATION, OPERATING AND MAINTENANCE MANUAL
PLEASE LEAVE WITH OPERATOR
A34/013 R17
ECN 8818 February 2019
1 |
P a g e

Advertisement

Table of Contents
loading

Summary of Contents for IMC SP Series

  • Page 1 SP-RANGE SP25 PEELER SP12 & SP25 – SERIES 4 INSTALLATION, OPERATING AND MAINTENANCE MANUAL PLEASE LEAVE WITH OPERATOR A34/013 R17 ECN 8818 February 2019 P a g e...
  • Page 2 SP-RANGE EC DECLARATION OF CONFORMITY (Guarantee of Production Quality) We, Imperial Machine Company Limited of: Unit 1, Abbey Road, Wrexham Industrial Estate, Wrexham, LL13 9RF Declare under our sole responsibility that the machine SP12 & SP25 – SERIES 4 As described in the attached technical documentation is in conformity with the Machine Safety Directive 98/37/EC and is manufactured under quality system BS EN ISO 9001.
  • Page 3: Table Of Contents

    SP-RANGE CONTENTS GUARANTEE ........................4 DELIVERY ......................... 4 SAMPLE RATING LABEL....................4 INTRODUCTION ....................... 5 YOUR PEELER ........................5 CONTROLS ........................6 INSTALLATION ......................6 & 7 WATER SUPPLY ........................ 7 WASTE OUTLET CONNECTION ..................7 WASTE EJECTOR ......................8 ELECTRICITY SUPPLY CONNECTION ................
  • Page 4: Guarantee

    SP-RANGE GUARANTEE This equipment is guaranteed by IMC for 2 Years from the date of purchase from IMC or from one of its stockists, dealers or distributors. The guarantee is limited to the replacement of faulty parts or products and excludes any consequential loss or expense incurred by purchasers.
  • Page 5: Introduction

    SP-RANGE INTRODUCTION This machine is intended for peeling potatoes. Its use may be extended to other root vegetables. It is not recommended to use this machine for peeling onions. YOUR PEELER SPLASH COVER CONTROL BOX DOOR CHUTE MOUNTING BRACKET DOOR HANDLE WASTE OUTLET P a g e...
  • Page 6: Controls

    · These instructions contain important information designed to help the user obtain the maximum benefit from the investment in an IMC SP Peeler. · Please read them carefully before starting work, and consult with the supplier in the event of any queries.
  • Page 7: Water Supply

    If required, secure with the hose clip supplied. Longer lengths of flexible hose are available from IMC on request. The waste outlet also incorporates a 2” BSP female thread for connection to standard 54mm (2”) waste pipe.
  • Page 8: Waste Ejector

    SP-RANGE WASTE EJECTOR The waste ejector is an optional fitting that dilutes the waste sludge to enable it to flow easily through the drains without fear of blockage. Waste Ejectors are not recommended in the follow circumstances; · A pipe run exceeding 15m between the machine and main drain ·...
  • Page 9: Electricity Supply Connection

    3 phases and earth. An equipotential earthing point is located on the back of the cylinder near the cable outlet if equipotential bonding is required. Should the mains lead become damaged, it must be replaced by an IMC service agent or qualified electrician in order to avoid a hazard.
  • Page 10: Commissioning

    The rotation direction of single phase units are set at the factory. If it is not rotating in the correct direction contact IMC. To change the rotation direction of three phase units, switch off the machine, isolate the supply and interchange any two phase wires.
  • Page 11: Safety

    SP-RANGE SAFETY All SP-Range peelers are controlled so that if the electricity supply is interrupted the machine will not restart automatically. All single phase SP-Range controls are fitted with a thermal trip. This ensures that the controls cannot overheat and become damaged. If the thermal trip cuts in, the machine will not run until it has cooled down and the peeler is switched off and on again.
  • Page 12: Do's And Don'ts

    SP-RANGE DO’S AND DON’TS Install on a level service. Ensure power supply isolator or socket is accessible with the peeler installed. Clean the machine after each period of use. Don’t PAT test single phase machines, as they have an inverter inside the control box, which invalidates any earth leakage tests.
  • Page 13: Maintenance

    Other than regular cleaning, the SP-Range of peelers require no maintenance by the end user. It is recommended that the unit is serviced by an IMC approved engineer at least once a year. The motor in the single phase units is controlled via an inverter. The following warnings must be observer before working on this unit.
  • Page 14: Wiring Diagram 1Ph Units

    SP-RANGE WIRING DIAGRAM 1PH UNITS 14 | P a g e...
  • Page 15: Wiring Diagram 3Ph Units

    SP-RANGE WIRING DIAGRAM 3PH UNITS 15 | P a g e...
  • Page 16: Parts Illustration

    SP-RANGE PARTS ILLUSTRATION 16 | P a g e...
  • Page 17: Spares Part List

    SP-RANGE SPARES PART LIST SP12 SP25 Item Part No Description Part No Description S58/593 SP12 LOW PEDESTAL S58/590 SP25 LOW PEDESTAL S58/594 SP12 HIGH PEDESTAL S58/591 SP25 HIGH PEDESTAL D18/050 SCREW M6X16MM CSK S.S D18/050 SCREW M6X16MM CSK S.S D20/038 NUT M5 FULL S.S.
  • Page 18 SP-RANGE S58/545 PEELER PLATE ASSY SP12 S58/546 PEELER PLATE ASSY SP25 M58/011 M1 SP12 RIM MOULDING M58/011 M2 SP25 RIM MOULDING SP12 (CAST) LID ASSEMBLY (Inc. spray SP25 (CAST) LID ASSEMBLY (Inc. spray S58/592 S58/589 nozzle) nozzle) J04/324 SPRAY NOZZLE - BRASS J04/324 SPRAY NOZZLE - BRASS S58/541...
  • Page 19: 1Ph Control Box Spare Parts List

    SP-RANGE 1PH CONTROL BOX SPARE PARTS LIST SP12p SP25 Item Part No Description Part No Description E58/096 MOUNTING BRACKET E58/096 MOUNTING BRACKET E58/097 WALL BRACKET (Not shown) E58/097 WALL BRACKET (Not shown) G76/031 M2 CONTROL BOX G76/031 M2 CONTROL BOX D21/052 SCREW M6 x 20 PAN SS D21/052...
  • Page 20: 3Ph Control Box Spare Parts List

    SP-RANGE 3PH CONTROL BOX SPARE PARTS LIST 15 16 17 SP12 SP25 Item Part No Description Part No Description E58/117 CONTROL BOX BRACKET E58/117 CONTROL BOX BRACKET E58/119 WALL BRACKET E58/119 WALL BRACKET G76/041 M1 CONTROL BOX (INC. LID) G76/041 M1 CONTROL BOX (INC.
  • Page 21: Ordering Spare Parts

    SERIAL NUMBER of the machine. This is to be found on the rating plate located near the supply cable. For installations outside the UK, please contact your supplier. For information on IMC spares and service support (if applicable), please call IMC on +44 (0)1978 661155. Alternatively, contact us via email or fax:...