Webasto D5W Z Manual page 9

Upgrade d5w z heater to auxiliary heating system c, ford galaxy
Table of Contents

Advertisement

Galaxy
Permanent positive connection
For all vehicle
The permanent positive connection is made at plug C6
(1) on the central electrics box P91
- Disconnect plug C6 (1)
Make the connections using the supplied 3-way
distributor (5), blade-type plug sleeves and insulation
sheaths as shown in the figure and the circuit diagram
in Figure 3 or 4.
- Use the supplied blade receptacles with detent
points
- Disconnect the red cable (1, 4) from the standard
wiring harness (6)
- Cut the red cable (1) from the standard main blade-
type fuse F 106, 110 A, to plug C6 (supply to
standard blade-type fuses F51 to F54) as shown in
the figure
IMPORTANT
The black insulation sheath is used on the blade-type
plug sleeve on the red cable (1) of the standard main
blade-type fuse!
- Connect both standard red cables (1, 4) and the red
cable (2) (supply to the Webasto wiring harness) as
shown in the figure using a 3-way distributor (5)
- Insulate the wiring harness (6) again and reconnect
plug C6 (3)
Earth connection
The earth connection is made on the standard earth
post (1) on the left above the fuse/relay holder.
- Secure the earth cable to the earth post (1)
D5W Z heater upgrade
1
6
5
4
1
11
1
2
12
3
13
9