INTRODUCTION Isochem pumps have all the standard features of Isochem Series pumps use sealless technology ECO Gearchem pumps such as continuous operation which eliminates the need for a rotary mechanical over wide temperature and pressure variations, self- seal and enables the pump to handle hazardous priming, constant volume pulsation free flow, able to fluids safely with zero leakage.
To check system operation, installation INSTALLATION of vacuum/pressure gauges in the (SEE FIGURE 1) suction and discharge lines is recommended. 1. Pump installation site should provide easy Keep suction lines short and straight to access for routine maintenance and where minimize friction loss to the pump.
Do not spring piping, either suction or OPERATION discharge when mating up to the pump. Use supports or hangers at intervals as required. 1. Prior to operation, make sure all suction piping is When necessary, provide for thermal air tight and clean. Check that electrical service to expansion and contraction so no strain is motor agrees with name plate ratings.
MAINTENANCE or otherwise abnormal operation, first refer to the troubleshooting section. If the problem cannot be resolved the pump must be The timing for maintenance of the pump is inspected for wear or damage. Isochem pumps established primarily on past performance. Each can be easily opened for cleaning and installation is different.
Page 8
are high and when the magnets come close RECOMMENDED SPARES together there is a strong tendency to snap together suddenly, possibly causing KOPkits. The basic Isochem KOPkit consists of pinching or worse to fingers. The attraction the following parts which are recommended as forces are strongest on the GMC12 and spares: GMC16 pumps.
& GMC4 SERIES GMC2 11. The gears can be removed from the shafts by removing one of the retaining rings and sliding REFERENCE DRAWING: SD2579 the gear off the shaft. DISASSEMBLY 12. Inspect all parts for signs of wear or damage. The maximum diametrical clearance (bearing Close discharge and suction valves.
Page 10
Reinstall pump in system, open inlet and Install the drive magnet assembly (Item 21) discharge valves and start pump. Monitor pump onto the motor shaft to the dimension shown in for 5-10 minutes for signs of binding, excessive Figure 4. If the motor is metric install the motor noise and motor amperage draw.
Page 11
side towards the front housing and retaining ring. end of the pump drive shaft (Item 4) and slide (Item 14). Note: Only new retaining rings should the driven magnet assembly (Item 18) off the be used on the driven magnet end due to the drive shaft.
Page 12
The driven magnet assembly (Item 24) can be GMH8 & GMC12/16 SERIES removed by carefully prying the retaining ring (Item 10) from the end of the pump drive shaft REFERENCE DRAWINGS: SD-2776, SD-2777, (Item 4). The driven magnet can then be SD-2781 removed from the shaft along with the coupling keys (Item 21) and other retaining ring.
BOLT-ON THERMAL JACKETS Next install another pair of wearplates, housing pins and the rear housing (Item 3). Install the INSTALLATION housing bolts (Item 18) and tighten. The following tools are required: Install the following parts onto the pump drive shaft in the order listed: retaining ring (Item 10), ...
removed. These traces neither affect a good fit nor inhibit NOTE: As bolts are tightened alternately good thermal performance. excess heat transfer cement will extrude from edges of jackets and at flange interfaces. When inside surfaces of jacket halves are Remove this excess cement with trowel.
TROUBLESHOOTING DIFFICULTY PROBABLE CAUSE REMEDY NO LIQUID DELIVERED Pump not primed. Prime pump. Suction and/or discharge valve Open valves. closed. Reverse rotation Wrong direction or rotation. Eliminate plug. Locate and repair leak. Suction plugged. Air leak in suction. Do not exceed vapor pressure of liquid.