Testing The Ethernet Installation - Digital Equipment VAX 4000 Model 100 Operator Instructions Manual

Hide thumbs Also See for VAX 4000 Model 100:
Table of Contents

Advertisement

3.5 Testing the Ethernet Installation

When you complete the network installation procedure, follow these steps to
test the installation:
1. Set the system unit on/off switch to the on ( | ) position.
2. Enter the following command to test the installation:
Run test 5F with the first parameter set to 0 (default) to test the SGEC chip
using internal loopback mode. An example of success is shown by the console
prompt returning without any messages as shown in the next two examples.
>>>t 5f
>>>
Another example of test success is shown with test 5F first parameter set
to 1 to test the SGEC chip using external loopback mode. This requires a
terminator on the selected ethernet port, either thin wire or thick wire. If the
test is run while connected to an active net, it may fail.
>>>t 5f 1
>>>
If the device fails the self-test, the system responds with a display similar to the
following:
>>>t 5f 1
? Test_Subtest_5F_18 Loop_Subtest=0E Err_Type=FF
Vec=010C Prev_Errs=0000
P5=00000000 P6=00000000
r0=00000054 r1=000082E2
r6=000082E2 r7=20008000
EPC=2005721A dser=0000 cesr=00000000 icsr=01 pcsts=F800 pcctl=FC13
cctl=00000007 bcetsts=03A0 bcedsts=0400 cefsts=00019200 nests=00
mmcdsr=00C6C600 mesr=00006000
>>>
If the device fails, see the VAX 4000 Model 100 Troubleshooting and Diagnostics
Information manual.
P1=00000001
P2=00000000
P7=00000000
P8=00000001
r2=00000001
r3=000082FA
r8=00008000
r9=20140758 r10=13000001 r11=2014044B
DE_SGEC.lis
P3=827DFF03 P4=00000000
P9=00000000 P10=00000000
r4=00008230 r5=00000040
Network Information 3–9

Advertisement

Table of Contents
loading

Table of Contents