Cosmos PS-7 Instruction Manual

With pyrolyzer unit
Hide thumbs Also See for PS-7:

Advertisement

New Cosmos - BIE
Instruction Manual
Gas detector PS-7 with pyrolyzer unit (PS-7-030-PU)
Be sure to store this instruction manual in a convenient location, and consult it
whenever necessary.
Operate this unit only after reading and fully understanding the content of this
manual.
This instruction manual was written for the pyrolyzer unit (option). Instructions
for the basic operations of the gas detector are provided separately in the
standard operation manual. Refer to the operation manual when necessary.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS-7 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Cosmos PS-7

  • Page 1 New Cosmos - BIE Instruction Manual Gas detector PS-7 with pyrolyzer unit (PS-7-030-PU) Be sure to store this instruction manual in a convenient location, and consult it whenever necessary. Operate this unit only after reading and fully understanding the content of this manual.
  • Page 2 Original release NC-BIE, FH  Copyright: New Cosmos - BIE, Heerhugowaard, 2015. No part of this document may be reproduced in any form whatsoever without the prior consent of the manufacturer. The contents of this document may be subject to change without prior notice.
  • Page 3 © New Cosmos - BIE Rev. 1.0.0 Caution  We recommend to replace the sensor unit and pyrolyzer element every six months. Always replace sensor unit and pyrolyzer elements that have reached their service life.  The replacement sensor unit and pyrolyzer elements must be installed before the shelf life has expired.
  • Page 4 © New Cosmos - BIE Rev. 1.0.0 YROLYZER CHECKS 1. Pull the cover lock knob down and release the lock. And after pulling it down further below, pull back the pyrolyzer case cover and remove it. 2. Status LED’s. Status LED’s are mounted on the pyrolyzer driver PCB. The pyrolyzer PCB is an integrated part of the pyrolyzer element.
  • Page 5 © New Cosmos - BIE Rev. 1.0.0 4. Pyrolyzer configuration Press the up/ down switch on the main unit, and verify that the pyrolyzer failure alarm is enabled (CON = 1). Warning  Be sure to check that the pyrolyzer failure alarm is set to ON. When regulator operations are carried out with the failure alarm OFF, the failure alarm will not work.
  • Page 6 © New Cosmos - BIE Rev. 1.0.0 YROLYZER EXCHANGE 1. Turn off the power source to the main unit 2. Pull the cover lock knob down and release the lock. And after pulling it down further below, pull back the pyrolyzer case cover and remove it.
  • Page 7 © New Cosmos - BIE Rev. 1.0.0 5. Exchange the pyrolyzer with a new one. The driver PCB is mounted with five screws. 6. Insert the pyrolyzer assembly in the case. Push the green part with your finger as shown below, and insert it completely (push it in as far as it will go).

This manual is also suitable for: