Johnson Controls 20 J ZJ Series Installation Manual page 4

15 - 25 ton 60 hertz
Hide thumbs Also See for 20 J ZJ Series:
Table of Contents

Advertisement

689670-BIM-A-0311
Nomenclature
Z U -A5 N08 A T A AA 6 0 1 2 4 A
Product Category
Z = A/C, Single Pkg., R-410A
Product Identifier
U = 11.8+ EER/14.0 SEER A/C
Nominal Cooling Capacity
-A3 = 3 Ton
-A4 = 4 Ton
-A5 = 5 Ton
Heat Type and Nominal Heat Capacity
(Unit Size Allowed)
C00 = Cooling Only. No heat installed
Single Stage Natural Gas Heat Options
A06 = 60 MBH Input Aluminized Steel,
Single Stage (-A3, -A4)
A08 = 80 MBH Input Aluminized Steel,
Single Stage (-A3, -A4, -A5)
A11 = 120 MBH Input Aluminized Steel,
Single Stage (-A3, -A4, -A5)
A16 = 160 MBH Input Aluminized Steel,
Single Stage (-A5)
B06 = 60 MBH Input Stainless Sleel,
Single Stage (-A3, -A4)
B08 = 80 MBH Input Stainless Steel,
Single Stage (-A3, -A4, -A5)
B11 - 120 MBH Input Stainless Steel,
Single Stage (-A3, -A4, -A5)
B16 = 160 MBH Input Stainless Steel,
Single Stage (-A5)
Two Stage Natural Gas Heat Options
N06 = 60 MBH Output Aluminized Steel,
Two Stage (-A3, -A4)
N08 = 80 MBH Input Aluminized Steel,
Two Stage (-A3, -A4, -A5)
N11 = 120 MBH Input Aluminized Steel,
Two Stage (-A3, -A4, -A5)
N16 = 160 MBH Input Aluminized Steel,
Two Stage (-A5)
S06 = 60 MBH Input Stainless Sleel,
Two Stage (-A3, -A4)
S08 = 80 MBH Input Stainless Steel,
Two Stage (-A3, -A4, -A5)
S11 - 120 MBH Input Stainless Steel,
Two Stage (-A3, -A4, -A5)
S16 = 160 MBH Input Stainless Steel,
Two Stage (-A5)
Electric Heat Options
E03 = 3 KW (-A3)
E06 = 6 KW (-A3, -A4, -A5)
E08 = 9 KW (-A3, -A4, -A5)
E15 = 15 KW (-A3, -A4, -A5)
E20 = 20 KW (-A4, -A5)
E23 = 24 KW (-A5)
4
3-5 Ton Model Number Nomenclature
Product Generation
6 = Sixth Generation
AA = None
AB = Phase Monitor
AC = Coil Guard
AD = Dirty Filter Switch
AE = Phase Monitor & Coil Guard
AF = Phase Monitor & Dirty Filter Switch
AG = Coil Guard & Dirty Filter Switch
AH = Phase Monitor, Coil Guard & Dirty Filter Switch
ZZ = If desired option combination is not listed above, ZZ will be assigned and configuration options will be
located in digits 15-18.
Voltage
T = 208/230-3-60
W = 460-3-60
X = 575-3-60
A = Std. Motor
B = Std. Motor/Econo./Barometric Relief (Downflow
Only)
C = Std. Motor/Econo./Power Exhaust (Downflow Only)
D = Std. Motor/Motorized Damper (Downflow Only)
E = Std. Motor/Horizontal Economizer (No Baro.)
F = Std. Motor/Slab Econo./Power Exhaust
(Downflow Only)
G = Std. Motor/Slab Econo./Barometric Relief
(Downflow Only)
N = Hi Static
P = Hi Static/Econo./Barometric Relief
(Downflow Only)
Q = Hi Static/Econo./Power Exhaust
(Downflow Only)
R = Hi Static/Motorized Damper (Downflow Only)
S = Hi Static/Horizontal Economizer (No Baro.)
T = Hi Static/Slab Econo./Power Exhaust
(Downflow Only)
U = Hi Static/Slab Econo./Barometric Relief
(Downflow only)
Product Style
A = Style A
B = Style B
C = Style C
Configuration Options (not required for all units)
These four digits will not be assigned until a quote is requested, or an order placed.
SS Drain Pan
CPC Controller, DFS, APS
Johnson Controller UNT 1126 (N2 protocol), DFS, APS
Honeywell Controller, DFS, APS
Novar Controller, DFS, APS
Simplicity IntelliComfort Controller
Simplicity IntelliComfort Controller w/Simplicity®Linc
2" Pleated filters
4" Pleated filters
BAS Ready Unit with Economizer
Shipping Bag
Any Combination of Additional Options that Don't Have an Option Code Pre-assigned
Additional Options
RC = Coil Guard, Shipping Bag & American Flag
TA = Technicoat Condenser Coil
TJ = Technicoat Evaporator Coil
TS = Technicoat Evaporator & Condenser Coils
EA = ElectroFin Condenser Coil
EJ = ElectroFin Evaporator Coil
ES = ElectroFin Cond & Evap Coils
Installation Options
A = No Options Installed
B = Option 1
C = Option 2
D = Options 1 & 2
E = Option 3
F = Option 4
G = Options 1 & 3
Airflow
H = Options 1 & 4
J = Options 1, 2 & 3
K = Options 1, 2, & 4
L = Options 1,3 & 4
M = Options 1, 2, 3, & 4
N = Options 2 & 3
P = Options 2 & 4
Q = Options 2, 3, & 4
R = Options 3 & 4
S = Option 5
T = Options 1 & 5
U = Options 1, 3, & 5
V = Options 1, 4, & 5
W = Options 1, 3, 4, & 5
X = Options 3 & 5
Y = Options 4 & 5
Z = Options 3, 4 & 5
1 = Disconnect
2 = Non-Pwr'd Conv. Outlet
3 = Smoke Detector S.A.
4 = Smoke Detector R.A.
5 = Pwr'd Conv. Outlet
Options