Checklist - Carrier 58CU0A Series Installation, Start-Up, Operating And Service And Maintenance Instructions

4-way multipoise, ultra low nox communicating, 80% afue gas furnace input capacities: 40,000 thru 100,000 btuh
Table of Contents

Advertisement

Checklist

1. Put away tools and instruments. Clean up debris.
2. Verify that switches SW1- -1 and SW1- -6 are OFF and oth-
er setup switches are set as desired. Verify that switches
SW1- -7 and SW1- -8 for the blower OFF DELAY are set as
desired per Table 10.
3. Verify that blower and burner access doors are properly
installed.
4. Cycle test furnace with room thermostat.
5. Check operation of accessories per manufacturer's
instructions.
6. Review User's Guide with owner.
7. Attach literature packet to furnace.
Table 12 – Blower Off Delay Setup Switch
DESIRED HEATING MODE
BLOWER OFF DELAY (SEC.)
90
120
150
180
Table 13 – Gas Rate (Cu Ft./Hr.)
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
5 Cu
REVOLU-
Cu
Cu
Ft.
TION
Ft.
Ft.
10
360
720
1800
11
327
655
1636
12
300
600
1500
13
277
555
1385
14
257
514
1286
15
240
480
1200
16
225
450
1125
17
212
424
1059
18
200
400
1000
19
189
379
947
20
180
360
900
21
171
343
857
22
164
327
818
23
157
313
783
24
150
300
750
25
144
288
720
26
138
277
692
27
133
267
667
28
129
257
643
29
124
248
621
30
120
240
600
31
116
232
581
32
113
225
563
33
109
218
545
34
106
212
529
35
103
206
514
36
100
200
500
37
97
195
486
38
95
189
474
39
92
185
462
40
90
180
450
41
88
176
439
42
86
172
429
43
84
167
419
44
82
164
409
45
80
160
400
46
78
157
391
47
76
153
383
48
75
150
375
49
73
147
367
SETUP SWITCH
(SW1--- 7 AND 1--- 8)
POSITION
SW1--- 7
SW1--- 8
OFF
OFF
ON
OFF
OFF
ON
ON
ON
SIZE OF TEST DIAL
SECONDS
FOR 1
1
2
5
REVOLU-
Cu
Cu
Cu
TION
Ft.
Ft.
Ft.
50
72
144
360
51
71
141
355
52
69
138
346
53
68
136
340
54
67
133
333
55
65
131
327
56
64
129
321
57
63
126
316
58
62
124
310
59
61
122
305
60
60
120
300
62
58
116
290
64
56
112
281
66
54
109
273
68
53
106
265
70
51
103
257
72
50
100
250
74
48
97
243
76
47
95
237
78
46
92
231
80
45
90
225
82
44
88
220
84
43
86
214
86
42
84
209
88
41
82
205
90
40
80
200
92
39
78
196
94
38
76
192
96
38
75
188
98
37
74
184
100
36
72
180
102
35
71
178
104
35
69
173
106
34
68
170
108
33
67
167
110
33
65
164
112
32
64
161
116
31
62
155
120
30
60
150
Table 14 – Gas Valve Outlet Pressure for Gas Heat Values at
(Tabulated Data Based on 40,000 BTUH Input for 0-ft (0m) to
5000-ft (1524-m) above sea level)
AVG. GAS
HEAT VALUE
ALTITUDE
AT ALTITUDE
RANGE
ft (m)
0
(0)
to
1000
1025
2000
1050
(610)
1075
1100
2001
(611)
to
3000
(914)
1000
3001
(915)
to
4000
(1219)
1000
4001
(1220)
to
5000
(1524)
1000
33
Altitude - - 40,000
SPECIFIC GRAVITY OF
NATURAL GAS
0.58
0.60
0.62
Gas Valve Outlet Pressure
(in. W.C.)
900
3.0
3.1
3.2
925
2.8
2.9
3.0
950
2.7
2.8
2.9
975
2.6
2.6
2.7
2.4
2.5
2.6
2.3
2.4
2.5
2.2
2.3
2.4
2.1
2.2
2.2
2.0
2.1
2.1
800
3.2
3.3
3.5
825
3.0
3.1
3.3
850
2.9
3.0
3.1
875
2.7
2.8
2.9
900
2.6
2.6
2.7
925
2.4
2.5
2.6
950
2.3
2.4
2.5
975
2.2
2.3
2.3
2.1
2.1
2.2
775
3.2
3.3
3.4
800
3.0
3.1
3.2
825
2.8
2.9
3.0
850
2.6
2.7
2.8
875
2.5
2.6
2.7
900
2.4
2.4
2.5
925
2.2
2.3
2.4
950
2.1
2.2
2.3
975
2.0
2.1
2.2
1.9
2.0
2.0
750
3.1
3.2
3.4
775
2.9
3.0
3.1
800
2.8
2.9
2.9
825
2.6
2.7
2.8
850
2.4
2.5
2.6
875
2.3
2.4
2.5
900
2.2
2.3
2.3
925
2.1
2.1
2.2
950
2.0
2.0
2.1
975
1.9
1.9
2.0
1.8
1.8
1.9
0.64
3.3
3.1
3.0
2.8
2.7
2.5
2.4
2.3
2.2
3.6
3.4
3.2
3.0
2.8
2.7
2.5
2.4
2.3
3.5
3.3
3.1
2.9
2.8
2.6
2.5
2.3
2.2
2.1
3.5
3.2
3.0
2.9
2.7
2.5
2.4
2.3
2.2
2.0
1.9

Advertisement

Table of Contents
loading

Table of Contents