Gas Furnace Checklist - Carrier 58SP0B Installation, Start-Up, Operating And Service And Maintenance Instructions

80 afue, non-communicating, single stage, variable 25-speed, ecm motor, 4-way multipoise, non-condensing gas furnace with intelisense
Table of Contents

Advertisement

58SP0B/58SP1B: Installation, Start–Up, Operating and Service and Maintenance Instructions

GAS FURNACE CHECKLIST

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
Fig. 53 – Gas Furnace Checklist
46
Thermostat
Humidifier
Furnace
Model
Equipment
Installation Date: ____________________________
GAS FURNACE CHECKLIST
Serial #
Furnace Orientation:
Indoor Coil
__________(F) high
LOW HEAT
LEAVING AIR TEMPERATURE
Firing rate = heat content (btu/cu. ft.) X size of the dial (cu. ft/rev) X # of rev. per 60 sec (rev/sec) X 3600 (sec/hr)
OR use the "Gas Rate" chart in the startup and adjustment section of the installation manual
Low fire_____________ in.
FIRING RATE:
MANIFOLD PRESSURE: High fire___________ in.
W.C.
Installed altitude __________________
Furnace Location_____________________________
Outdoor Unit
ORIFICE #_____________
____Upflow
W.C.
Downflow
**Supply pressure should be checked with furnace and all other gas appliances running
Horizontal Right
(CLOCKED METER FOR NAT. GAS – assure only furnace is running)
Horizontal Left
Example- (1050 btu/cu. ft.) X (0.5 cu. f t ./rev.) X (2 revs./60sec) X (3600 sec/hr)= 63,000 btu/hr
Gas Adjustment
HIGH HEAT_________________ btu/hr
LOCAL GAS HEAT CONTENT_____________(btu/cu. ft.)
______________________________
SPECIFIC GRAVITY________/cu. ft.
__________(F) high
(contact your local gas utility-not required for propane)
RETURN AIR TEMPERATURE
INLET SUPPLY PRESSURE**
_________ (F) low
______________ in.
_________ (F) low
W.C.
btu/hr
METAL:
TEMPERATURE RISE
B Vent
Connector Type:
ft.
Chimney Liner
Concentric
(circle one)
Termination Type:
Pipe Dia_____________ # of Elbows_____________ Total Length _____________
+90 % VENTING SYSTEM
The supply temperature should be measured away from the line of sight of the Heat Exchanger
Temperature rise is equal to the supply air temp minus the return air temp @ steady state operation.
(circle one)
_________ (F) low
2 pipe (std)
Vent Dia________Total Ht.________
Termination Locat i on:
Vent Conn. Dia_______ Conn. Length ______
(circle one)
Single Wall
Roof
Connector Rise Above Furnace _________
Sidewall
MID-EFFICIENCY VENTING SYSTEM
B vent
__________(F) high
ft.
ft.
# of Elbows________
ft.
A230014