Prior to maintenance work:
• Shut off condensate inlet (if necessary
switch off compressor).
General cleaning of QWIK-PURE
(recommended every 12 months)
Empty main tank *
1
Clean main tank.
Note:
Do not add any cleaning agents (surfac-
tants or flammable cleaners)! They impair
the filter efficiency.
After cleaning:
2
Insert new OEKOSORB filter set
Insert new filter mat.
3
Fill QWIK-PURE unit with clean water
* Refer to start-up procedures on
page 16
After maintenance work
• Open condensate inlet.
QWIK-PURE 100