Download Print this page

Resetting Keypad - SDC EntryCheck 923 Installation Instructions And Setup Manual

Advertisement

Solid-state Output #3 On-time
Sets the length of time Output #3 activates when triggered.
Press: 2 3 # Seconds #
Seconds=Output time in seconds (0-60), 99=Toggle Mode
Solid-state Output #4 On-time
Sets the length of time Output #4 activates when triggered.
Press: 2 4 # Seconds #
Seconds=Output time in seconds (0-60), 99=Toggle Mode
Door Ajar Timer
Sets the amount of time the door may be held open after an
authorized access. The DOOR AJAR output will activate after the
time expires.
Press: 25 # Seconds #
Seconds=Held open time in seconds (1-60)
Beep Sounds on Keystrokes
Selects whether or not the keypad beeps as each key is pressed.
Press: 4 0 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Main Relay
Selects whether or not the keypad beeps during Main Relay
activation.
Press: 4 1 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Auxiliary Relay
Selects whether or not the keypad beeps during Auxiliary Relay
activation.
Press: 4 2 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Output #3
Selects whether or not the keypad beeps during Output #3
activation.
Press: 4 3 # Sound #
Sound=1 for Yes, =0 for No
Beep Sounds During Output #4
Selects whether or not the keypad beeps during Output #4
activation.
Press: 4 4 # Sound #
Sound=1 for Yes, =0 for No
P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd
Default: 02 Seconds
Default: 02 Seconds
Default: 60 Seconds
Default: Yes
Default: No
Default: No
Default: No
Default: No
Rev F
05-19
Page 6
Keypad Lockout Count
Sets the number or incorrect entry code attempts allowed
before the keypad "locks out".
Press: 5 0 # Attempts #
Attempts=Number of attempts before lockout (2-7)
Anti-Pass Back Time
Sets the length of time an entry code will not function after it is
used.
Press: 5 1 # Minutes #
Minutes=Time in minutes (1-4), 0=No Anti-passback
Selects mode for Keypad LED Backlight
Selects whether or not the keypad back light stays OFF, lights for 30
seconds when activated or stays ON.
Press: 52 # Output #
0 = Light always OFF
1 = 30 sec light when activated (default)
2 = Light always ON
Changing the Beeper Sound Level
The Keypad's beeper can be set to high or low level.
Remove jumper JP1 to reduce beeper sound level.
Changing the 6-Digit Master Programming Code
Press: 9 8 # Master Code # Master Code #
Master Code=The new 6-digit Master Programming Code
New master code: ____________

RESETTING KEYPAD

Master Reset
CAUTION: Performing a master reset will clear the
entire memory of the 923 and return all programmable
options to the factory default values. ALL ENTRY
CODES WILL BE ERASED. NOTE: The Master Code will
NOT be reset.
STEP 1 Disconnect power from the keypad.
STEP 2 Press and hold down the * and # keys.
STEP 3 Apply power to the keypad, continue holding the keys
down until the red indicator starts flashing
STEP 4 Release the keys. The red and yellow indicators will
remain lit until the process is complete, then the
yellow indicator will go out.
Resetting the Master Code
STEP 1 Remove the 923 from the wall and disconnect
power from the keypad.
STEP 2 Locate & Remove jumper at JP2. Reference page 2.
STEP 3 Re-apply power. You will get a single beep and
the yellow LED will flash momentarily.
STEP 4 Replace jumper on JP2.
THE MASTER PROGRAMMING CODE IS NOW 123456.
Default: 3 Tries
Default: No Anti-Pass Back
Default: 30 Seconds

Advertisement

loading

This manual is also suitable for: