QuickStart Programming
You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 923
EntryCheck™ is in programming mode. Use the option codes to program each function. After the new data entry is complete for
each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the
programming has been accepted. The red indicator will light if any programming data is entered incorrectly or the function is rejected.
If a red indicator is seen, the entire function (option code + data) will have to be fully re-entered.The keypad will remain in
programming mode until
Set default parameters (first time use)
Step 1. Enter: #9# 123456#
Step 2. Enter: 03# 4#
Step 3. Enter: 21# 5#
Step 4. Enter:
#
Assign a user code
Step 1. Enter: #9# 123456#
Step 2. Enter: 01# 002# 2580# 2580# 1#
Step 3. Enter:
#
Test your new user
Enter PIN code '2580#'. The green indicator should illuminate and the main relay
should activate, unlocking the door for 5 seconds.
Adding additional user codes
Once the code length and relay time has been set you do not need to set them again for
additional users.
To add additional users:
Step 1. Enter: #9# 123456#
Step 2. Enter: 01# 003# 2222# 2222# 1#
Step 3. Repeat Step 2 to enter another unique User # & PIN code OR skip to Step 4.
Step 4. Enter:
#
Deleting a user code
Step 1. Enter: #9# 123456#
Step 2. Enter: 02# 002# 002#
Step 3. Enter:
#
TO POWER SUPPLY
Fig. 2 Wiring Pigtail Color Code
P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd
# is pressed or after 30 seconds of inactivity.
Enter the program mode (default master code)
Set the entry code length to 4 digits
Set the main relay activation time for 5 sec.
Exit programming mode
Enter the program mode (default master code)
Assign User 002 with a PIN code of '2580'.
Activate the main relay when entered.
Exit programming mode
Enter the program mode (default master code)
User 003 has been created with a PIN code of
'2222#' to activate the main relay
Exit programming mode
Enter the program mode (default master code)
User 2 has been deleted.
Exit programming mode
BLACK
}
KEYPAD POWER
RED
12 or 24 VOLTS
AC OR DC
BLACK
NO
}
AUXILIARY RELAY
WHITE
COM
2 AMPS @ 28VDC MAX
ORANGE
NC
}
MAIN RELAY
5 AMPS @ 28VDC MAX
Rev F
05-19
GROUND
{
OUTPUT #4
*
OUTPUT #3
GROUND
NOT USED
REQUEST TO EXIT
GROUND
SENSE
Page 2
RED/GREEN
POWER/ACCESS
INDICATOR
KEYPAD
POWER
AUXILIARY
RELAY
JP2
ANTI-TAMPER
SWITCH
BLACK
REQUEST-TO-EXIT
PINK/SALMON
SWITCH
BLUE
[N/O]
BLACK
GREEN
VIOLET
NO
BLACK
GRAY
*
AUXILIARY OUTPUTS
100mA MAX TO COMMON
CAUTION
IF THE UNIT IS AC POWERED, MAKE SURE
THAT THE SECONDARY OF THE SYSTEM IS
ISOLATED FROM EARTH GROUND
YELLOW
"PROGRAM"
INDICATOR
FRONT
JP1
BACK
WIRE
HARNESS
(E1-E8)
Grn Wire
To earth ground
MAIN
RELAY
DOOR POSITION
SWITCH
[N/C]
NC
C
C
NO

Advertisement