Download Print this page

SDC EntryCheck 923 Installation Instructions And Setup Manual

Advertisement

Quick Links

801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 •
www.sdcsecurity.com • E-mail: service@sdcsecurity.com
The 923 Indoor/Outdoor Keypad Surface Mount EntryCheck™ is a digital
keyless entry system designed for access control applications. The
keypad is integrated in a heavy cast vandal resistant housing, designed to
be mounted on a rugged, surface mounting plate and may be mounted in
a standard single-gang electrical box. The indoor/outdoor backlit keys
have bright, easy-to-read graphics.
Up to 500 entry codes, from 1 to 6 digits in length, can be programmed.
They can activate either, or both of the relay outputs. The "anti-passback"
feature prevents using the same code again before the programmed time
elapses.
All system indicators are long-lasting, solid state LEDs. Two indicators
show the status of the entry system. The left indicator lights red to
indicate power, then turns green when access is granted. The right yellow
LED flashes when the keypad is in programming mode. An internal
sounder beeps when each key is pressed. An internal jumper sets the
sounder volume high or low
The SENSE input can be used two ways. If programmed for "door sense"
the input is wired to a normally closed switch on the door to detect when
the door is opened or closed. Forced entry or door ajar situations can
then be detected. Using door sense, the "Auto-relock" feature will prevent
"tailgating" by turning off the Main Relay output immediately when the
door is closed after access has been granted. If the SENSE input is
programmed for "inhibit", the input can be wired to a "service" switch or
automatic timer that will disable the Main Relay when required.
The REQUEST-TO-EXIT input can be wired to a pushbutton to provide
codeless activation of Main Relay, Auxiliary Relay, Output #3 or Output #4
(programmable).
The ALARM SHUNT output activates when access is granted. This
output can be wired to shunt alarm contacts on the access door/gate to
prevent triggering of an alarm when authorized access occurs.
The 923 EntryCheck™ is powered from a 12 or 24V AC or DC source.
The EEPROM memory retains all entry codes and programming, even
without power. An internal jumper is provided to reset the master code.
The Main Relay has a 5 Amp capacity. The Auxiliary Relay has a 2 Amp
capacity. Two solid state outputs, capable of switching 100 mA to
common, are programmable to signal forced entry, door ajar, lockout,
alarm circuit shunting, request-to-exit, and keypad active conditions.
P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd
INSTALLATION INSTRUCTIONS
923 EntryCheck
Rev F
05-19
Page 1
TM
Features
Keypad programmable
500 user codes
4 to 6 digit user codes
4 independent outputs
4 independent timers
2 Form C relay contacts
2 solid state open collector outputs
Program entry codes to activate one or
two relays
Disable input
Door sense input
Request-to-exit/enter input
Keypad tamper lockout
Timed anti-passback
Anti-tailgate
Two LED status indicators
Tactile key feel
Audible code entry verification
12 or 24V, AC or DC operation
SPECIFICATIONS
Mechanical
Dimensions: 1.750" W x 7.3125" H x 1.375" D
(1.4375" wall projection)
Electrical
Input Voltage: 12/24 Volts AC or DC
Operating Current: 30 mA typical, 150 mA max
Output Ratings
Main Relay: Form "C" 5 Amps @ 28 Volts max
Auxiliary Relay: Form "C" 2 Amp @ 28 Volts max
Type: Solid state outputs (Outputs #3 & #4)
Short-to-common 100 mA @ 24 VDC maximum
Environmental
Temperature: -4°F to 140°F (-20°C to 60°C)
Humidity: 5% to 95% non-condensing
Any suggestions or comments to this instruction or
product are welcome. Please contact us through
our website or email engineer@sdcsecurity.com

Advertisement

loading

Summary of Contents for SDC EntryCheck 923

  • Page 1 801 Avenida Acaso, Camarillo, Ca. 93012 • (805) 494-0622 • www.sdcsecurity.com • E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 923 EntryCheck The 923 Indoor/Outdoor Keypad Surface Mount EntryCheck™ is a digital keyless entry system designed for access control applications. The Features keypad is integrated in a heavy cast vandal resistant housing, designed to be mounted on a rugged, surface mounting plate and may be mounted in Keypad programmable a standard single-gang electrical box.
  • Page 2 QuickStart Programming You must first enter programming mode to perform any function. The yellow indicator will blink slowly showing that the 923 EntryCheck™ is in programming mode. Use the option codes to program each function. After the new data entry is complete for each function , the yellow indicator will flash quickly while the data is being stored and the green indicator will light briefly if the programming has been accepted.
  • Page 3: Keypad Wiring

    KEYPAD WIRING See Fig. 3 for an example of a basic door installation. The keypad is Door Sensor Switch mounted adjacent to the door. An electric door strike is mounted in the door jamb to release the door lock. A door contact switch is mounted on top of the door jamb for detecting when the door is open.
  • Page 4: Factory Defaults

    Programming the 923 To Hold the Output Re-entering a Command After a Mistake SDC’s EntryCheck™ products have a programmable “Toggle Mode” available for each relay and solid-state output. When an If the red indicator lights, signaling an incorrect entry, or an...
  • Page 5 (Typical Programming cont.) Select Keypad Lockout Output Default: No Output See the following example that sets entry codes 1234 for normal and 5678 for toggle operation. Sets which output activates when the keypad is “locked out” after too many incorrect entry code attempts. The lockout time is 60 seconds.
  • Page 6: Resetting Keypad

    Solid-state Output #3 On-time Default: 02 Seconds Keypad Lockout Count Default: 3 Tries Sets the length of time Output #3 activates when triggered. Sets the number or incorrect entry code attempts allowed before the keypad “locks out”. Press: 2 3 # Seconds # Press: 5 0 # Attempts # Seconds=Output time in seconds (0-60), 99=Toggle Mode Attempts=Number of attempts before lockout (2-7)
  • Page 7: Wall Mount

    MULLION MOUNT 1.750 7.3125 1.375 WALL MOUNT 4X Mount at holes With supplied screws and hole expansion anchors P:\INSTALLATION INST\Access Controls\INST-923\INST-923.vsd Rev F 05-19 Page 7...

This manual is also suitable for:

923 entrycheck