ST-01R roller blind control unit
Instructions for installation and use
Safety guidelines
Basic guidelines
The ST-01R controller can be safely installed and used provided all of the following instructions of installation and use as well as obligatory health
and safety regulations are adhered to.
The installation and repairing of electrical equipment should be carried out only by persons with appropriate legal qualifications.
Reconstructing or making changes to the ST-01R controller is forbidden. During the guarantee period repairs only the manufacturer may carry out
repairs. Even after the guarantee period has expired only original parts and accessories may be used.
The guarantee is only valid when the ST-01R controller has been used in accordance with the manufacturer's instructions. The boundary values
given in the technical specifications must NOT be exceeded under any circumstances.
Supplementary safety regulations
When installing, using or carrying out maintenance work all binding health and safety regulations should be followed. Particular attention should be
paid to the following:
1.
European Standards
2.
Fire regulations
3.
Accident avoidance regulations
.
The following comments serve as general guidelines to the application of INEL drivers with other devices. These guidelines must
always be adhered to when installing and operating these devices
Warning – this signal warns of possible damage to the control system or other equipment if appropriate safety measures are not taken.
Before installing the control system and setting the end switches check all bolt connections are properly fastened.
Danger – this signal indicates danger to the user's life and health if appropriate safety measures are not taken.
Follow all health and safety regulations relevant to the equipment (e.g. gates, roller blinds) used.
When changing fuses the equipment must be first disconnected from the mains, the fuses changed and only then may the equipment be
reconnected to the mains.
The ST-01R controller should be installed in accordance with appropriate safety regulations and with appropriate safety devices.
INEL equipment connected to the mains beyond a building's safety fuse system needs to be installed with its own safe disconnecting
devices (e.g. safety fuses and safety switches) in such a way so as to ensure that all the units may be easily and safely cut off from the
mains.
Electric wiring and cables should be regularly checked to ensure the insulation is intact and there are no breaks in the wire.
If any damage to the wiring is found, the unit should be immediately disconnected from the mains and the damaged wiring replaced.
Before connecting any equipment, one should first make sure that it is adapted to be used with the local voltage in the mains.
Do not allow children to play with any of the control devices.
Keep all remote control devices out of the reach of children.
Observe the opening or shutting of the blinds, shutters, awnings or gates and ensure all persons stand clear until the operation is
completed.
Control system operators need to undergo preliminary instruction and training and also be made aware of all the potential dangers that
can be encountered. A person should only be authorised to use the control system only once the employer, administrator or owner is
satisfied that that person has been properly instructed.
It is not permitted to dispose of waste equipment together with other waste. Dispose only in specially designated areas. The household
plays a key role in the recycling of waste equipment. By correct sorting of waste, including waste equipment and batteries, household
members ensure that the equipment is not disposed together with household waste, but in specially designated areas, and thus may be
used again after recycling.
GENERAL COMMENTS REGARDING HAZARDS AND SAFETY PRECAUTIONS
PERSONAL SAFETY WARNING
1

Advertisement

loading

Summary of Contents for Inel ST-01R

  • Page 1 Safety guidelines Basic guidelines The ST-01R controller can be safely installed and used provided all of the following instructions of installation and use as well as obligatory health and safety regulations are adhered to. The installation and repairing of electrical equipment should be carried out only by persons with appropriate legal qualifications.
  • Page 2: Controller Description

    CONTROLLER DESCRIPTION ST-01R The ST-01R controller is a device used to control locally or remotely the operation of roller blinds and shutters. The device is intended for flush mounting in a double depth wall box. Local control is achieved with a manual button connected to the manual input. The controller has a deadman function - a short press of the manual on/off button starts a full cycle of opening or closing the roller blind (the time of applying voltage to the motor is factory set at 100 seconds).
  • Page 3 Registering remote controls Controlling the drive with any channel from any remote control connected to the ST-01R is possible after registering that channel for the given controller. There are two ways of accessing the programming option for ST-01R controllers: 1. After pressing the S1 button on the controller.
  • Page 4 PIL – 05/09/19PM Detailed operating instructions are attached to the remote control. The PIL-05/19/19PM remote has five buttons:  ▲"up" button  ■ "stop" button  ▼ "down" button  ► "right" button  ◄ "left" button Starting roller blinds: To start the given drive, press the ▲...
  • Page 5 PIL – 01DL Detailed operating instructions are attached to the remote control. The PIL-01DL remote has five buttons:  ▲"up" button  ■ "stop" button  ▼ "down" button Starting roller blinds: To start the given drive, press the ▲ "up" button (to open) or the ▼ "down" button (to close). You can stop the drive by pressing the ■...
  • Page 6 PIL – 01PT This is a single channel, flush-mounted remote control working with ST-01R and ST-01RL controllers and drives with built-in radio receivers (marked "R"). It is installed in a wall box. The PIL-01PT remote is powered with a CR-2032 battery and fitted with a connector for any shutter switch.

This manual is also suitable for:

St-01rzSt-01rs