Enter the Telco fault input zone number.
Do ndt
program this zone for Open/Close option.
Enter the zone number(s) for all zones which are to
trigger on low inputs or relay contact openings.
Enter the zone numbers for which it is desired
to permit a 16 second delay before reporting
an alarm.
Enter the zone number for the zone which is to
report openings and closings after a 16 second
delay. Do not program this zone as the Telco fault
input channel.
Only one zone
can be an
openlclose zone.
Enter the zone which are to report restored
conditions.
Note that the Telco Fault zone will
always
report
a restore,
and
need
not be
programmed for this option.
Enter the zone numbers which have Ademco
Mode supervision (an option in VECTOR 3000, for
. .
example).
CONTROL OUTPUT OPTIONS
CAUTION. When using control outputs, note that transceiver power rasets
(as when entetfng Program Mode) can affect the state of any device
connaoted to the control outputs, and that appropriate measurea, such as
time delaya, should bs taken to avoid undesirable results due to tha
device's change of state.
~
The 7920SE
provides one control output
terminal (TB1 -2), with the option to program
three additional control outputs. Press "N" if
no additional control outputs are required and
skip to the last question. If additional control
outputs are required, press "Y". The display
then asks:
IMPORTANT! ff "Four Control Outputs" Is
aelectect, the LEDs WILL NOT flash according to
their radio functions described earlier. They will
light in accordance with their Control Output
programming.
Note that if Control Outputs are used, the
keyboard will beep to indicate return to Normal
mode, rather than light the LEDs. If the
transceiver cannot return to Normal mode (ex. a
parameter set incorrectly), the keyboard will
beep rapidly.
-15-