Preparing for Operation
4
.

About items displayed on the screen

4-1.
Standby state
State
Shows the current state and the current
time when the oil concentration detector
is standing by.
Automatic operation
State
Shows these items when detecting the
sample water inlet pressure after
operation the bilge separator.
Shows "warm-up" and a remaining
warming-up time.
Example of display during "operation"
<
Oil concentration
Alarm1 oil alarm
point
Example of display during "operation"
Oil concentration Alarm1 oil alarm
point
Washing
State
Shows these items when the washing is
in progress.
Shows the remaining washing time
(in seconds).
Display item
Current state: standby state
Year / Month / Day
Display item
Year / Month / Day
Current state: Operating
Details: warm-up now
Current state: Operating
Current hours: minutes: seconds
State of signal output from
the 3-way valve
ON = The bilge drains.
Current hours: minutes: seconds
Current state: Operating
State of signal output from the
3-way valve
Equal to or more than oil alarm point
OFF = The bilge does not drain.
Display item
Current state: Operating
Details: Washing in progress
Hours : Minutes : Seconds
Hours : Minutes : Seconds
Remaining time
Oil concentration
Less than oil alarm point
Oil concentration
Remaining time
Page. 8
Description
The oil concentration detector enters the
standby state when the pressure at the
sample water inlet is lower than 0.03
MPa.
Description
The oil concentration detector
automatically starts to run when
detecting a sample water inlet pressure
of 0.03 MPa or higher.
Waits for a specified warm-up time (in
seconds) until the state of sample water
becomes stable for measurement.
The bilge cannot be drained
independently of where the oil alarm
point exists.
The "AL1" alarm lamp is off when the oil
concentration is less than Alarm1 oil
alarm point.
The "AL1" alarm lamp blinks at the
same time.
The bilge does not drain.
Description
Feed fresh water into the detection tube
to wash the inside of the tube when the
sample water pressure goes under 0.03
MPa after the bilge pump stops.